![Baumer PosCon OXH7 Manual Download Page 17](http://html1.mh-extra.com/html/baumer/poscon-oxh7/poscon-oxh7_manual_2710829017.webp)
en_BA_OXH7_PosCon_TCP_IP.docx
17/98
Baumer Electric AG
Friday, June 15, 2018 12:44:11 PM/tof V1.0 ANW_81184815
Frauenfeld, Switzerland
2.5.1
Pin assignments and connection diagrams
M12 8-pin
M12 4-pin
7
6
1
2
5
4
3
8
4
1
3
2
Z
Z
Z
Z
alarm
0V
n.c.
out
n.c.
n.c.
(8)
(7)
+Vs
RD
(2)
(4)
(5)
(6)
BN
YE
GY
PK
BU
sync in
(1)
WH
(3)
GN
power
supply
push-
pull
Rx-
Rx+
Tx-
Tx+
BU (2)
OG (4)
YE (3)
WH (1)
Ethernet
Color
Function
Description
Pin 1
WH = white
Tx+
TX+ (BI_DA+)
Pin 2
BU = blue
Rx+
RX+ (BI_DB+)
Pin 3
YE = yellow
Tx-
TX- (BI_DA-)
Pin 4
OG = orange
Rx-
RX- (BI_DB-)
Color
Function
Description
Pin 1
WH = white
n.c.
Not used
Pin 2
BN = brown
+Vs
Voltage supply (+15…+28 VDC)
Pin 3
GN = green
n.c.
Not used
Pin 4
YE = yellow
out
Switching output, push-pull
Pin 5
GY = gray
alarm
Alarm output, push-pull
Pin 6
PK = pink
n.c.
Not used
Pin 7
BU = blue
0V
Ground GND
Pin 8
RD = red
sync in
Synchronization input
NOTE
We recommend that you connect unused cables to GND (0V).
M12 8-pin
M12 4-pin