en_BA_OXH7_PosCon_TCP_IP.docx
14/98
Baumer Electric AG
Friday, June 15, 2018 12:44:11 PM/tof V1.0 ANW_81184815
Frauenfeld, Switzerland
2.4 Alignment
To achieve as reliable and exact measurement values as possible, the following hints and tips for mounting
should be followed.
2.4.1
The reference surface
If the height of the object is to be measured from a specific surface or if the sensor is to be mounted at an
angle of up to ±30°, then the reference surface must be teached using the Flex Mount function.
The following points must be satisfied for teaching the reference surface:
•
The reference surface must be within the measuring range of the sensor (Sdc-Sde)
•
The sensor may be inclined at a maximum angle of ±30° to the reference surface
•
The "maximum unevenness of the reference surface"
1
must not exceed the maximum value
•
The length of the reference surface must not be less than the "minimum reference surface length"
1
value
1
In accordance with chapter Sensor data sheet
Reference surface
Object
NOTE
The reference surface…
•
should be as even as possible
•
should cover the entire measuring range (width) if possible
•
can be teached in using the Flex Mount function
Min. reference
surface length
Angle
(here = 0°)