en_BA_OXH7_PosCon_TCP_IP.docx
68/98
Baumer Electric AG
Friday, June 15, 2018 12:44:11 PM/tof V1.0 ANW_81184815
Frauenfeld, Switzerland
Address
Parameter description
Data type
200
Status
uint16_t
201
Quality
uint8_t
202
SwitchOut OR AlarmOut:
SwitchOut -> 0x0001
AlarmOut -> 0x0002
0: Nothing
1: Switch Out
2: Alarm Out
3: Switch and Alarm Out
uint16_t
203-204
Average [mm]
float32_t
205-206
Max [mm]
float32_t
207-208
Min [mm]
float32_t
209-210
Delta [mm]
float32_t
211-212
Standard Deviation [mm]
float32_t
213-214
Measurement Rate [Hz]
float32_t
215-216
Time Stamp [sec]
uint32_t
217-218
Time Stamp [usec]
uint32_t
Address 250 – Get Teachable Range
Returns the min./max. range which the switching points can be set to.
Function
Input register (FUNCTION 04)
Address
250
Length
14
Address
Parameter description
Data type
250-251
Min SP1
float32_t
252-253
Max SP1
float32_t
254-255
Min SP2
float32_t
256-257
Max SP2
float32_t
258-259
Min Hysteresis [mm]
float32_t
260-261
Maximum Hysteresis [mm]
float32_t
4.2.4.1