en_BA_OXH7_PosCon_TCP_IP.docx
38/98
Baumer Electric AG
Friday, June 15, 2018 12:44:11 PM/tof V1.0 ANW_81184815
Frauenfeld, Switzerland
Reference
With "Reference", it is possible to shift the reference surface in both directions following the teaching process.
This enables, for example, the thickness of the auxiliary plate required during teaching to be deducted again,
or the reference surface to be suppressed.
Example using an auxiliary plate
To compensate for unevenness in the reference surface, a temporary auxiliary plate can be used for the
teaching process.
This plate should be as flat as possible and must conform to the "minimum length of reference surface"
1
. The
plate must be positioned parallel to the reference surface below it. The thickness of this plate is not important
as long as it is within the field of view of the sensor. The thickness of the auxiliary plate can be deducted again
at the end of the process using "Reference".
Teach-in reference surface
Reference = Thickness of the auxiliary
plate
Auxiliary plate
Reference surface
This is the redefined reference surface, everything below it is suppressed