en_BA_OXH7_PosCon_TCP_IP.docx
62/98
Baumer Electric AG
Friday, June 15, 2018 12:44:11 PM/tof V1.0 ANW_81184815
Frauenfeld, Switzerland
406-407
Maximal Fixed Trigger Time [us] (command does not care
which number is written)
uint32_t
Address 410 – Laser On/Off
Function
Holding register (FUNCTION 03/06/16)
Address
410
Length
1
Address
Parameter description
Data type
410
Laser State
uint16_t
Address 500 – Store Setting
Stores the currently active parameters in a parameter setup.
Function
Holding register (FUNCTION 03/06/16)
Address
500
Length
1
Access
Write Only
Address
Parameter description
Data type
500
Parameter Setup No. (1, 2, or 3)
uint16_t
Address 501 – Load Setting
Loads a parameter setup.
Function
Holding register (FUNCTION 03/06/16)
Address
501
Length
1
Access
Write Only
Address
Parameter description
Data type
501
Parameter Setup No. (1, 2, or 3)
uint16_t
Address 502 – Reset Setting
Resets a parameter setup to the default setting.
4.2.3.1
4.2.3.1
4.2.3.1
4.2.3.1