4.2.4
Modbus TCP commands: Input register
Overview of index commands for input register function 04
Address
Length
Command
0
33 Vendor Information
40
46 Device Information
90
5 Frontend Version
100
6 Read Eth Config
120
6 MAC Address
130
16 Support E-Mail
150
10 Get Field of View Limits
180
6 Get Flex Mount Limits
200
19 Get All Measurements
250
14 Get Teachable Range
300
4 Live Monitor
400
1 Unsaved Config
401
1 Active Setting Number
410
29 Get Setting 1
450
29 Get Setting 2
490
29 Get Setting 3
600
108 Get Block Mode Memory 0
708
108 Get Block Mode Memory 1
816
108 Get Block Mode Memory 2
924
108 Get Block Mode Memory 11
1032
108 Get Block Mode Memory 12
1140
108 Get Block Mode Memory 13
1248
108 Get Block Mode Memory 14
1356
108 Get Block Mode Memory 15
1464
108 Get Block Mode Memory 16
1572
108 Get Block Mode Memory 3
1680
108 Get Block Mode Memory 4
1788
108 Get Block Mode Memory 5
1896
108 Get Block Mode Memory 6
2004
108 Get Block Mode Memory 7
2112
108 Get Block Mode Memory 8
2220
108 Get Block Mode Memory 9
2328
108 Get Block Mode Memory 10
Address 0 – Vendor Information
In the vendor information, the Baumer ID and the vendor name are stored and returned.
Function
Input register (FUNCTION 04)
4.2.4.1
4.2.4.1