Operating Manual for
BAUER LINESTAR 9000 with hose feed
25
By means of the transformer installed, the oscillator box can either be connected to a 230V AC / 50Hz supply line
or it can be supplied directly by a battery of 24V DC (
2 x 12V DC
). A voltage of 24V with a frequency of 1,5KHz is
supplied directly to the cable laid below ground. The magnetic field generated thus is detected by the steering
antennas and the voltage induced is evaluated in the so-called track unit.
Important information
:
At first putting into operation, the below ground cable will generally be connected to the "long connection" terminal
of the oscillator box. If the system works duly, the green LED will be lit.
First putting into operation is exclusively carried out under the presence of a BAUER technician or of an authorized
dealer and it must not be carried out by unqualified personnel.
Connection
"
short
" is appropriate for a conductor loop of max. 1 – 15 Ohm impedance and a max. current
of 600 mA.
Connection
"
long
" is appropriate for a conductor loop of max. 3 – 75 Ohm impedance and a max. current of
300 mA.
Setting screw for amperage
for adjusting the signal strength (see
15 First Start up)
.
setting screw
for amperage
Summary of Contents for LINESTAR 9000
Page 1: ...OPERATING MANUAL for BAUER LINESTAR 9000 with hose feed Version XII 2013 850 9898 ...
Page 82: ...74 Operating Manual for BAUER LINESTAR 9000 with hose feed ...
Page 94: ...86 Operating Manual for BAUER LINESTAR 9000 with hose feed 23 4 LINESTAR LINEAR CONTROL ...
Page 101: ...Operating Manual for BAUER LINESTAR 9000 with hose feed 93 ...
Page 104: ...96 Operating Manual for BAUER LINESTAR 9000 with hose feed 23 5 5 END TOWER BOX STANDARD ...
Page 106: ...98 Operating Manual for BAUER LINESTAR 9000 with hose feed 23 5 7 END TOWER BOX WITH END STOP ...
Page 110: ...102 Operating Manual for BAUER LINESTAR 9000 with hose feed 23 6 BOOSTER PUMP FOR END GUN ...