60
Operating Manual for
BAUER LINESTAR 9000 with hose feed
21.5
AUTOMATIC INTERVAL CONTROL
If the end gun is equipped with a big nozzle for a large spray range, the application rate at the end of the system is
too high. This will be compensated by an automatic interval control which opens and closes automatically a 2”
valve gate and controls the operating time of the end gun.
Operating and break times of the end gun can be set at the TIME/BREAK relay.
21.6
AUTOMATIC „ON/OFF” AND INTERVAL CONTROL
This control unit combines the two above mentioned controls for the end gun and the booster pump..
21.7
TOWER ALIGNMENT SWITCH
This switch is mounted outside on the base plate of the alignment control. It allows the forward or backward move
of the tower without having to open the alignment control. This device facilitates system alignment at first start-up or
after changing the operating site.
21.8
RUNNING LIGHT
Mounted on the end tower or on the central unit. This light is shining as long as the LINESTAR is operating.
21.9
END STOP
If it is necessary to stop the system precisely at the field end, system shut-down takes place at the end tower. A
contact limit switch mounted on the end tower is actuated by a shut-off frame which is placed at the field end in the
track of the last tower. The machine stops.
Abschaltstange
cut-off bar
tringle d’arrêt
barra de desconexión
Abschaltrahmen
cut-off frame
cadre d’arrêt
cuadro de desconexión
Grenztaster
barrier sensing device
interrupteur-limiteur
sensor de limite
Summary of Contents for LINESTAR 9000
Page 1: ...OPERATING MANUAL for BAUER LINESTAR 9000 with hose feed Version XII 2013 850 9898 ...
Page 82: ...74 Operating Manual for BAUER LINESTAR 9000 with hose feed ...
Page 94: ...86 Operating Manual for BAUER LINESTAR 9000 with hose feed 23 4 LINESTAR LINEAR CONTROL ...
Page 101: ...Operating Manual for BAUER LINESTAR 9000 with hose feed 93 ...
Page 104: ...96 Operating Manual for BAUER LINESTAR 9000 with hose feed 23 5 5 END TOWER BOX STANDARD ...
Page 106: ...98 Operating Manual for BAUER LINESTAR 9000 with hose feed 23 5 7 END TOWER BOX WITH END STOP ...
Page 110: ...102 Operating Manual for BAUER LINESTAR 9000 with hose feed 23 6 BOOSTER PUMP FOR END GUN ...