Operating Manual for
BAUER LINESTAR 9000 with hose feed
59
21 OPTIONS
21.1
LOW PRESSURE SHUT-OFF
The supply pressure on the central unit is monitored by a pressure gauge. If the supply pressure is lower than the
minimum pressure set on the pressure gauge, the shut-off valve closes (
option
), and the Linestar shuts down.
This will only happen under the condition the “WET-DRY” switch has been set to
“WET”.
If it has been put to “DRY” position the pressure gauge is inoperable..
When turning the switch to “DRY” position the machine runs without irrigating (
dry run
). This may be necessary
when moving the LINESTAR to a parking position because of natural rainfall.
21.2
ELECTRIC SHUT-OFF VALVE (CENTRAL UNIT)
An electric shut-off valve in the supply line of the central tower is closed automatically, if the LINESTAR shuts down
by malfunction.
21.3
END GUN
To increase the irrigated strip width or the system spraying range inside the swivelling area, an end gun can be
mounted at the end of the LINESTAR overhang. It may spray along the whole irrigation strip or only along parts of
it.
If the end gun is thought to operate in interval mode, an automatic “ON/OFF” control unit must be installed.
21.4
BOOSTER PUMP FOR END GUN
In most cases the end gun needs a higher pressure than the other nozzles of the LINESTAR.
An electric booster pump mounted on the end tower generates the necessary operating pressure for the end gun.
The booster pump is connected to the gun on the overhang by a pressure hose..
CAUTION
Summary of Contents for LINESTAR 9000
Page 1: ...OPERATING MANUAL for BAUER LINESTAR 9000 with hose feed Version XII 2013 850 9898 ...
Page 82: ...74 Operating Manual for BAUER LINESTAR 9000 with hose feed ...
Page 94: ...86 Operating Manual for BAUER LINESTAR 9000 with hose feed 23 4 LINESTAR LINEAR CONTROL ...
Page 101: ...Operating Manual for BAUER LINESTAR 9000 with hose feed 93 ...
Page 104: ...96 Operating Manual for BAUER LINESTAR 9000 with hose feed 23 5 5 END TOWER BOX STANDARD ...
Page 106: ...98 Operating Manual for BAUER LINESTAR 9000 with hose feed 23 5 7 END TOWER BOX WITH END STOP ...
Page 110: ...102 Operating Manual for BAUER LINESTAR 9000 with hose feed 23 6 BOOSTER PUMP FOR END GUN ...