Operating Manual for
BAUER LINESTAR 9000 with hose feed
17
9.1.1.3
VOLTMETER
Indicates the voltage between phases L1 and L2.
9.1.1.4
SWITCH ”LINESTAR OFF-ON”
Establishes power supply of control panel. In the “ON” position, the system can be started or stopped with an
operation on the
LINESTAR PRO
control panel.
9.1.1.5
SWITCH SAFETY CIRCUIT ON-OFF”
If this switch has been put to position “ON”, the whole system will be shut down in case of malfunction
(misalignment
). The position “OFF” is only to be used by an expert person for system alignment.
Whenever the machine is running the switch must be in position “ON” in order to guarantee a safe
unattended run!
9.1.1.6
SWITCH “END GUN OFF-ON”
In position “ON” the end gun is in use, in position “OFF” it is out of use.
9.1.1.7
SWITCH “GENERATOR OFF-ON”
The generator unit shuts down automatically.
ON
when system runs into safety circuit.
in case of pressure loss in supply line
at end stop
at intermediate stop, e.g. when changing the connection of the supply hose.
Use this setting for regular run!
OFF
In this position the generator unit does not shut down automatically for the above mentioned reasons.
This setting is used for:
aligning
the
LINESTAR
dry run of LINESTAR
9.1.1.8
SWITCH “EMERGENCY STOP”
Control unit is cut off power
Summary of Contents for LINESTAR 9000
Page 1: ...OPERATING MANUAL for BAUER LINESTAR 9000 with hose feed Version XII 2013 850 9898 ...
Page 82: ...74 Operating Manual for BAUER LINESTAR 9000 with hose feed ...
Page 94: ...86 Operating Manual for BAUER LINESTAR 9000 with hose feed 23 4 LINESTAR LINEAR CONTROL ...
Page 101: ...Operating Manual for BAUER LINESTAR 9000 with hose feed 93 ...
Page 104: ...96 Operating Manual for BAUER LINESTAR 9000 with hose feed 23 5 5 END TOWER BOX STANDARD ...
Page 106: ...98 Operating Manual for BAUER LINESTAR 9000 with hose feed 23 5 7 END TOWER BOX WITH END STOP ...
Page 110: ...102 Operating Manual for BAUER LINESTAR 9000 with hose feed 23 6 BOOSTER PUMP FOR END GUN ...