O&M Manual for PowerKit
M26 Series Diesel Engine
18
2. Product
2.1 Rating Definitions
Rating definitions
Running conditions
COP
Continuous power
Engines of this rating provide unlimited hours of
usage in a constant 100% load.
No overload capability is allowed.
PRP
Unlimited Prime Rated Power
Engines of this rating provide unlimited hours of
usage in a variable load application.
The average load factor should not exceed 70% of
the engine’s prime power rating for each 250 hours
duration; with a maximum number of 500 opera-
tional hours at 100% prime power rating.
An overload capability of 10% is available, however,
is limited to a period of 1 in every 12 hours.
ESP
Emergency Standby Power
Engines of this rating provide power output with a
varying load for the duration of a main power net-
work failure.
The average load factor should not exceed 80% of
the en
gine’s standby power rating for each 24 hours
run-cycle.
A maximum operational hour of the engine is 200
hours. This includes an annual maximum of 25
hours per year at the standby power rating.
No overload capability is allowed. The engine is not
to be used for maintained utility paralleling applica-
tions.
Summary of Contents for 12M26 Series
Page 1: ...1 1003195965 ...
Page 2: ...2 Operation and Maintenance Manual for PowerKit M26 Series Diesel Engine GDMB26V1901 ...
Page 31: ...O M Manual for PowerKit M26 Series Diesel Engine 31 12M26MP Figure 3 2B 12M26 Mounting ...
Page 78: ...O M Manual for PowerKit M26 Series Diesel Engine 78 6 6 Engine Maintenance Log ...
Page 79: ...O M Manual for PowerKit M26 Series Diesel Engine 79 ...