Operation the measuring system
24
PETRO 3003 VOLUTANK Operating Instructions, Software version pyramid 2.5.19, BA 151014 (04.12.2020))
4.2.5
Empty test
When configuring the measuring system, it is possible to specify that loading
may only proceed if an empty test takes place within a specified time (
Config-
uration menu/Control Parameter/
Max. Delay of Empty Test
). If this time has
elapsed, the empty test prompt will appear on opening the loading menu.
An empty test may only be run without any hoses connected!
● Press "YES" to start the empty test.
Loading may only proceed if the wetleg sensor is still displaying "empty" at the
end of an empty test and no measurement can be registered in the compart-
ment.
The empty test can be omitted if the same product will be loaded and if allowed
by the configuration
(Configuration menu/Control Parameter/ Loading onto Rest).
You can also run an empty test at any other time (cf. section 6.8).