Additional Functions Menu (within a tour)
87
PETRO 3003 VOLUTANK Operating Instructions, Software version pyramid 2.5.19, BA 151014 (04.12.2020)
6.8
Empty test
To check whether the compartments are empty, you can run an empty test.
If an empty test is required before loading (depending on the configuration),
the request to carry out an empty test is displayed if it has not yet been carried
out or the specified time after the empty test has expired.
Parameters for configuring the empty test
Control-Parameter
Max. Delay of Empty Test
Before loading, an empty test must have taken place within the configured
time. 0: empty test not required.
Default setting: 60 min.
Empty Test despite Volume
yes: The empty-test is also performed when still product is detected in the
compartment.
Logical Output 15
Switching the compressed air to the bottom valves during an empty test