Operation the measuring system
26
PETRO 3003 VOLUTANK Operating Instructions, Software version pyramid 2.5.19, BA 151014 (04.12.2020))
4.2.7
Manual opening of bottom valves
The system can be configured to prevent the bottom valves from opening au-
tomatically in order to prevent fluids from leaking even if hoses are not cor-
rectly connected.
In this case you have to open the bottom valves manually after checking that
the hose coupling is correctly fitted.
● Touch the numerical key corresponding to the number of the compartment
on which you want to open the bottom valve.
If you want to load several compartments, you will have to open each of
the other relevant bottom valves individually.
If the "SAFE" system is enabled, a compartment can only be opened if a product
code has been duly scanned.
● When the compartments are loaded, close all bottom valves with
the
STOP
button.