Operation the measuring system
20
PETRO 3003 VOLUTANK Operating Instructions, Software version pyramid 2.5.19, BA 151014 (04.12.2020))
4
Operation the measuring system
4.1
Tour start
In order to load and deliver products, you need to start a tour.
● Touch the "Tour Start" softkey.
Information about the available compartments are displayed. If the vehicle
is equipped with an external angle measuring system, the longitudinal and
transverse inclination angle of the vehicle are also displayed.
Status indication on the display
Wetleg sensor
Bottom valve
Measurement display
Compartment status
not wet
closed
stable
Empty
Empty
wet
open
not stable
Rest
Residual
Filling level in not
measurable range,
Residual sensor
not wetted (Empty-
ing time not ex-
pired).
Error
increasing
decreasing
State sealing
Compartment sealed
Error
Compartment not sealed
60
max. residual
quantity
Filling level in not
measurable range
Residual
sensor
wetted
.
2400
currently mea-
sured level
The compartment status is displayed with a gray background until the emptying time has not expired.
Compartment N
o
.
Product
State wetleg sensor
State bottom valve
State measurement
State sealing (cf. section 4.4)
Compartment state