System monitoring
111
PETRO 3003 VOLUTANK Operating Instructions, Software version pyramid 2.5.19, BA 151014 (04.12.2020)
7.2
Attention monitoring
Attention monitoring can be configured to increase safety during operation. It
is checked whether actions are carried out on the measuring system within
certain time intervals.
Monitoring takes place as long as an order is being processed.
E.g. If the system is not operated within 25 minutes (*), a
small notification window appears on the display.
If no operation is found after further 5 minutes (*), a large
notification window is displayed. If a delivery is in progress,
it will be stopped.
If no operation takes place after further 2 minutes (*), an
e-mail is sent to a specified address and output 101 is ac-
tivated if this is configured.
(
*
)
The specified values are default settings for configura-
ble times).