13. Lamp House & Lamp replacement
5
Image 13-31
9. Secure the xenon lamp cathode with the hexagon socket head cap screw (reference 1 image 13-32), spring washer (reference
2 image 13-32 and plain washer (reference 3 image 13-32). Fasten the screw with a torque of
2.5Nm
(1.84 lbf*ft). Use a torque
wrench with a 5 mm Allen socket.
Caution:
Make sure that both pins (reference 11 image 13-32) of the cathode adapter remain engaged in the foreseen slots.
3
1
2
11
.5 Nm
2.5
.5
2.5 Nm
Image 13-32
10.Install the side cover of the Lamp House and fasten the two quarter turn screws (reference 4 image 13-33) of the cover.
Note:
Ensure that the quarter turn screws turning wires are
fl
ush with the cover or interference will occur while inserting the
Lamp House into the projector.
4
Image 13-33
116
R5905961 ZEUS 09/03/2015
Summary of Contents for ZEUS
Page 1: ...ZEUS Installation safety manual R5905961 00 09 03 2015 ...
Page 17: ...2 Safety PR Image 2 2 R5905961 ZEUS 09 03 2015 13 ...
Page 26: ...3 Getting started 22 R5905961 ZEUS 09 03 2015 ...
Page 44: ...6 Lenses Lens selection 40 R5905961 ZEUS 09 03 2015 ...
Page 84: ...10 Starting up 80 R5905961 ZEUS 09 03 2015 ...
Page 96: ...11 Scheimpflug 92 R5905961 ZEUS 09 03 2015 ...
Page 104: ...12 Convergence 100 R5905961 ZEUS 09 03 2015 ...
Page 128: ...13 Lamp House Lamp replacement 124 R5905961 ZEUS 09 03 2015 ...
Page 160: ...16 Removal and installation of the projector covers 156 R5905961 ZEUS 09 03 2015 ...
Page 176: ...18 Pin configurations 172 R5905961 ZEUS 09 03 2015 ...
Page 184: ...19 Environmental information 180 R5905961 ZEUS 09 03 2015 ...