13. Lamp House & Lamp replacement
Image 13-21
8. Remove the protection cap from the anode connector.
Image 13-22
9. Remove the anode wire lug from the anode connector. For this, use a 17mm open end wrench and a 17mm nut driver. Hold one
nut (reference 6 image 13-23) with the open end wrench while releasing the other nut (reference 9 image 13-23) with the nut
driver. Note that there is a plain washer (reference 8 image 13-23) in front of the wire lug (reference 7 image 13-23).
Tip:
To avoid losing the plain washer and bolt (reference 8 & 9 image 13-23), place these back immediately after lug removal.
7
6
8
9
Image 13-23
10.Remove the cathode adapter from the xenon lamp by releasing the hexagon socket head cap screw (reference 10 image 13-24)
of the adapter as illustrated. Use a 5mm Allen wrench.
Note:
The xenon lamp has a cathode pin with screw thread (reference 11 image 13-24).
11
10
Image 13-24
R5905961 ZEUS 09/03/2015
111
Summary of Contents for ZEUS
Page 1: ...ZEUS Installation safety manual R5905961 00 09 03 2015 ...
Page 17: ...2 Safety PR Image 2 2 R5905961 ZEUS 09 03 2015 13 ...
Page 26: ...3 Getting started 22 R5905961 ZEUS 09 03 2015 ...
Page 44: ...6 Lenses Lens selection 40 R5905961 ZEUS 09 03 2015 ...
Page 84: ...10 Starting up 80 R5905961 ZEUS 09 03 2015 ...
Page 96: ...11 Scheimpflug 92 R5905961 ZEUS 09 03 2015 ...
Page 104: ...12 Convergence 100 R5905961 ZEUS 09 03 2015 ...
Page 128: ...13 Lamp House Lamp replacement 124 R5905961 ZEUS 09 03 2015 ...
Page 160: ...16 Removal and installation of the projector covers 156 R5905961 ZEUS 09 03 2015 ...
Page 176: ...18 Pin configurations 172 R5905961 ZEUS 09 03 2015 ...
Page 184: ...19 Environmental information 180 R5905961 ZEUS 09 03 2015 ...