13. Lamp House & Lamp replacement
11
10
2.5Nm
Image 13-25
3. Install the anode wire lug (reference 7 image 13-26) onto the anode socket of the Lamp House as illustrated. Take care of
wire orientation (must
fi
t through slot of white Te
fl
on part). Use an open-end wrench of 17 mm to hold the
fi
rst nut (reference 6
image 13-26) while fastening the second nut (reference 9 image 13-26) with a torque of
9Nm
(6.64 lbf*ft) using a torque wrench.
Ensure that there is a
fl
at washer (reference 8 image 13-26) between the second nut and f the wire lug (reference 7 image 13-26).
Warning:
A torque of
9Nm
(6.64 lbf*ft) must be applied to fasten the nuts. Make sure that there is no tension on the anode
wire of the xenon lamp.
Note:
Alter tightening the two nuts, the connector should still be “
fl
oating”.
7
6
8
9
14
9Nm
9Nm
Image 13-26
Tip:
Write down the serial number of the xenon lamp. You will need this while updating the lamp parameters after installation
of the xenon lamp. The serial number of the xenon lamp is engraved in the neck of the xenon lamp.
4. Click the protection cap onto the anode socket.
Caution:
Ensure the cap is properly installed. It may not come loose from the socket.
Image 13-27
5. Remove the protective packing from the xenon lamp and gently insert the xenon lamp (cathode
fi
rst) into the Lamp House as
illustrated. While inserting the lamp, rotate it slightly,
engaging the pins
(reference 11 image 13-28) of the cathode adapter in
the foreseen slots. This is to ensure the lamp cathode is completely inserted. Keep supporting the anode of the lamp with one
hand once the xenon lamp is in position. It’s important that the anode
cable is freely routed
as shown in the illustration.
Caution:
Ensure that you wear protective clothing, a full face shield and protective gloves.
Tip:
Retain the protective packaging for future use (you will need it when replacing the next lamp).
114
R5905961 ZEUS 09/03/2015
Summary of Contents for ZEUS
Page 1: ...ZEUS Installation safety manual R5905961 00 09 03 2015 ...
Page 17: ...2 Safety PR Image 2 2 R5905961 ZEUS 09 03 2015 13 ...
Page 26: ...3 Getting started 22 R5905961 ZEUS 09 03 2015 ...
Page 44: ...6 Lenses Lens selection 40 R5905961 ZEUS 09 03 2015 ...
Page 84: ...10 Starting up 80 R5905961 ZEUS 09 03 2015 ...
Page 96: ...11 Scheimpflug 92 R5905961 ZEUS 09 03 2015 ...
Page 104: ...12 Convergence 100 R5905961 ZEUS 09 03 2015 ...
Page 128: ...13 Lamp House Lamp replacement 124 R5905961 ZEUS 09 03 2015 ...
Page 160: ...16 Removal and installation of the projector covers 156 R5905961 ZEUS 09 03 2015 ...
Page 176: ...18 Pin configurations 172 R5905961 ZEUS 09 03 2015 ...
Page 184: ...19 Environmental information 180 R5905961 ZEUS 09 03 2015 ...