7. Input & Communication
The connectors used for all Ethernet ports are of the type RJ45, which is compatible with standard RJ45 cable
connector. Straight (most common) as well as cross linked network cables can be used. The 2 ports are
functionally identical. Both ports are connected via the projector switch (Auto sensing enabled).
Cinema Controller functions:
•
Ethernet Communication to ICP, Media block or Link decryptor.
•
Virtual COM port (RS232) to BARCO Controller on the USB-IN port.
•
Standardized 3D interface on board.
•
GPIO controls
•
Lensholder motors (stepper motors)
•
Stores lens
fi
les and lens type / Controls lens
•
Lens motor drivers (DC motors)
•
Controls lamp power supply
•
Stores SNMP key
•
Stores Barco IP address and host name
•
Handles reporting of errors, version info & Barco logs to Communicator
•
Controls ICP board
•
Controls Dolby 3D color wheel
•
Controls and monitors keypad (Button module)
•
Controls and monitors status lights
•
Stores Macro
fi
les, Input
fi
les, Lens
fi
les, 3D
fi
les and Light Sensor Calibration
fi
le (LSC)
Virtual comport (RS232 serial communication)
The USB-IN port of the communication interface supports RS232 serial communication. You can use the RS232 input port to connect
a local PC to your ZEUS projector projector. This way you can con
fi
gure and control your ZEUS projector projector from your local
PC.
Do not forget to set the projector’s baud rate (default = 115200) to match that of the computer.
Advantages of using RS232 serial communication:
•
easy adjustment of the projector via PC (or MAC).
•
wide range of control possibilities.
•
sending data to the projector (update).
•
copying data from the projector (backup).
RS232
An Electronic Industries Association (EIA) serial digital interface standard specifying the characteristics of the commu-
nication path between two devices using either D-SUB 9 pins or D-SUB 25 pins connectors. This standard is used for
relatively short-range communications and does not specify balanced control lines. RS-232 is a serial control standard
with a set number of conductors, data rate, word length and type of connector to be used. The standard speci
fi
es com-
ponent connection standards with regard to computer interface. It is also called RS-232-C, which is the third version
of the RS-232 standard, and is functionally identical to the CCITT V.24 standard. Logical ’0’ is > + 3V, Logical ’1’ is < -
3V. The range between -3V and +3V is the transition zone.
52
R5905961 ZEUS 09/03/2015
Summary of Contents for ZEUS
Page 1: ...ZEUS Installation safety manual R5905961 00 09 03 2015 ...
Page 17: ...2 Safety PR Image 2 2 R5905961 ZEUS 09 03 2015 13 ...
Page 26: ...3 Getting started 22 R5905961 ZEUS 09 03 2015 ...
Page 44: ...6 Lenses Lens selection 40 R5905961 ZEUS 09 03 2015 ...
Page 84: ...10 Starting up 80 R5905961 ZEUS 09 03 2015 ...
Page 96: ...11 Scheimpflug 92 R5905961 ZEUS 09 03 2015 ...
Page 104: ...12 Convergence 100 R5905961 ZEUS 09 03 2015 ...
Page 128: ...13 Lamp House Lamp replacement 124 R5905961 ZEUS 09 03 2015 ...
Page 160: ...16 Removal and installation of the projector covers 156 R5905961 ZEUS 09 03 2015 ...
Page 176: ...18 Pin configurations 172 R5905961 ZEUS 09 03 2015 ...
Page 184: ...19 Environmental information 180 R5905961 ZEUS 09 03 2015 ...