Field Service Manual
December 2003
Page 255 of 276
Optic
Error : Spurious chartcon reset
Due to interference on the AC power supply, the optics controller board(carlass)
inside the carriage got a false reset command.
►
Ground of 3phase and monophase should be interconnected.
►
Spikes on 3phase voltage
►
Ground cable to the plotter
►
Ground of Carlass cable from carriage to elektronic rack should be connected
Error : Chartcon time out error in shinit
Unable to initialise shutter
►
Voltages still present on carlass?
‼
Connector JF2.
Connection
1&2
:
gnd
17&18
:
+12V
21&22
:
-5V
‼
Connector JE1
Connection
1&4
:
gnd
2 : 5V (shutter cable disconnected)
►
Carlass, Maccon, shutter
►
Cable from electronic rack to carlass. Measure cable.
►
Groundcable(cable electronic rack to carlass )connected at carriage and
electronic rack ?
Error : Tune error / EPC Tune error : cannot tune beam
Unable to switch on a beam
►
Are the ‘driver boards’ present during initialising the machine?
‼
Powersupply driver rack working. Led on front is working?
‼
Check all electrical cable connections for driver rack.
►
Circuit braker for laser rack still activated ?
►
Broken diod cable !
►
Laser or laser powersupply
Summary of Contents for SilverWriter 800
Page 6: ...Field Service Manual December 2003 Page 6 of 276 ...
Page 8: ...Field Service Manual December 2003 Page 8 of 276 ...
Page 18: ...Field Service Manual December 2003 Page 18 of 276 ...
Page 20: ...Field Service Manual December 2003 Page 20 of 276 ...
Page 24: ...Field Service Manual December 2003 Page 24 of 276 ...
Page 95: ...Field Service Manual December 2003 Page 95 of 276 Multi FilmFeeder solid state panel ...
Page 96: ...Field Service Manual December 2003 Page 96 of 276 ...
Page 122: ...Field Service Manual December 2003 Page 122 of 276 ...
Page 130: ...Field Service Manual December 2003 Page 130 of 276 ...
Page 134: ...Field Service Manual December 2003 Page 134 of 276 ...
Page 168: ......
Page 172: ...Field Service Manual December 2003 Page 172 of 276 ...
Page 174: ...Field Service Manual December 2003 Page 174 of 276 ...
Page 187: ...Field Service Manual December 2003 Page 187 of 276 ...
Page 216: ...Field Service Manual December 2003 Page 216 of 276 ...
Page 220: ...Field Service Manual December 2003 Page 220 of 276 Main directory structure ...
Page 225: ...Field Service Manual December 2003 Page 225 of 276 Adding a DPF file in the plotter queue ...
Page 227: ...Field Service Manual December 2003 Page 227 of 276 Stop logging ...
Page 234: ...Field Service Manual December 2003 Page 234 of 276 ...
Page 240: ...Field Service Manual December 2003 Page 240 of 276 ...
Page 242: ...Field Service Manual December 2003 Page 242 of 276 ...
Page 246: ...Field Service Manual December 2003 Page 246 of 276 ...
Page 248: ...Field Service Manual December 2003 Page 248 of 276 ...
Page 252: ...Field Service Manual December 2003 Page 252 of 276 ...
Page 268: ...Field Service Manual December 2003 Page 268 of 276 ...
Page 270: ...Field Service Manual December 2003 Page 270 of 276 ...
Page 274: ...Field Service Manual December 2003 Page 274 of 276 ...