Field Service Manual
December 2003
Page 111 of 276
Although the input air must be free of oil and water, two extra filters
are built into the SilverWriter . These filters should be checked monthly. A
viewing glass may show if water or oil has entered. After shutting off
the air, the filters can be removed for closer examination.
Warning
When you don't switch off the compressed air ,any oil and water - present -
will be projected into the environment when you remove the filters !
Filter Unit Maintenance Procedure
- Switch OFF the power from the machine.
- Remove the left side cover plate .
- Switch OFF compressed air by turning the valve 1/4 turn to the right
- Wait until all noise from escaping air has stopped and the manometer
reading has dropped to 0.
- Check status filters.
- Remove filters by turning 1/8 turn to the left (bayonet lock).
- Clean filters. Remove water and oil, if present.
- Put filters back (1/8 turn to the right, with bayonet lock).
- Switch on compressed air by turning the valve 1/4 turn to the left.
- Verify the pressure (6 bar) on the manometer.
- Install the cover in place (push until click is heard).
Caution
When a lot of water or oil is found inside the filter, you should
examine your compressor, drier and compressed air lines outside the
SilverWriter. In case of suspected problems on the
Imagesetter, you should shutdown the machine completely and
call ManiaBarco for support.
Summary of Contents for SilverWriter 800
Page 6: ...Field Service Manual December 2003 Page 6 of 276 ...
Page 8: ...Field Service Manual December 2003 Page 8 of 276 ...
Page 18: ...Field Service Manual December 2003 Page 18 of 276 ...
Page 20: ...Field Service Manual December 2003 Page 20 of 276 ...
Page 24: ...Field Service Manual December 2003 Page 24 of 276 ...
Page 95: ...Field Service Manual December 2003 Page 95 of 276 Multi FilmFeeder solid state panel ...
Page 96: ...Field Service Manual December 2003 Page 96 of 276 ...
Page 122: ...Field Service Manual December 2003 Page 122 of 276 ...
Page 130: ...Field Service Manual December 2003 Page 130 of 276 ...
Page 134: ...Field Service Manual December 2003 Page 134 of 276 ...
Page 168: ......
Page 172: ...Field Service Manual December 2003 Page 172 of 276 ...
Page 174: ...Field Service Manual December 2003 Page 174 of 276 ...
Page 187: ...Field Service Manual December 2003 Page 187 of 276 ...
Page 216: ...Field Service Manual December 2003 Page 216 of 276 ...
Page 220: ...Field Service Manual December 2003 Page 220 of 276 Main directory structure ...
Page 225: ...Field Service Manual December 2003 Page 225 of 276 Adding a DPF file in the plotter queue ...
Page 227: ...Field Service Manual December 2003 Page 227 of 276 Stop logging ...
Page 234: ...Field Service Manual December 2003 Page 234 of 276 ...
Page 240: ...Field Service Manual December 2003 Page 240 of 276 ...
Page 242: ...Field Service Manual December 2003 Page 242 of 276 ...
Page 246: ...Field Service Manual December 2003 Page 246 of 276 ...
Page 248: ...Field Service Manual December 2003 Page 248 of 276 ...
Page 252: ...Field Service Manual December 2003 Page 252 of 276 ...
Page 268: ...Field Service Manual December 2003 Page 268 of 276 ...
Page 270: ...Field Service Manual December 2003 Page 270 of 276 ...
Page 274: ...Field Service Manual December 2003 Page 274 of 276 ...