Carriage Air Bearings
Air Bearings
When initializing the SilverWriter, 24 VDC sets VG
valve to switch air to the air bearings, via 1 regulator.
DO NOT CHANGE THE FACTORY SETTINGS.
The air bearings can be switched on by the following command:
LTL > HRDWINIT
-> always includes setting VG valve.
(air to air bearings)
When no air is present, the carriage is locked. The permanent
magnets in the carriage will hold the carriage against the linear motor
(weak iron rod underneath the linear motor windings).
The carriage floats on 5 air bearings:
•
two horizontal air bearings lifting the carriage up from the
horizontal granite block surface.
•
two vertical air bearings keeping the upper part away from the
vertical granite block surface above the linear motor.
•
one vertical air bearing in the center of the bottom part, keeping
it away from the vertical granite block surface underneath the linear
motor.
Diagnostics on Air Bearings
The distance between the carriage magnets and the linear motor surface
is about 0.36mm. This can be checked as follows:
•
cut out two pieces (4x100 cm) of thick film (7 mil or 0.18 mm)
•
it should be possible to insert these two pieces of film in the gap
between the magnets and the linear motor.
Caution
When water or oil has reached the air bearings and granite block,
you should shutdown the machine completely and call ManiaBarco for
support.
You should also check the air filter unit and you should examine your
compressor, drier and compressed air lines outside the SilverWriter .
Different carriage installations can have a small difference in carriage
adjustments.
Malfunctioning of the air bearings will result in ERRORS when operating
the Imagesetter:
Summary of Contents for SilverWriter 800
Page 6: ...Field Service Manual December 2003 Page 6 of 276 ...
Page 8: ...Field Service Manual December 2003 Page 8 of 276 ...
Page 18: ...Field Service Manual December 2003 Page 18 of 276 ...
Page 20: ...Field Service Manual December 2003 Page 20 of 276 ...
Page 24: ...Field Service Manual December 2003 Page 24 of 276 ...
Page 95: ...Field Service Manual December 2003 Page 95 of 276 Multi FilmFeeder solid state panel ...
Page 96: ...Field Service Manual December 2003 Page 96 of 276 ...
Page 122: ...Field Service Manual December 2003 Page 122 of 276 ...
Page 130: ...Field Service Manual December 2003 Page 130 of 276 ...
Page 134: ...Field Service Manual December 2003 Page 134 of 276 ...
Page 168: ......
Page 172: ...Field Service Manual December 2003 Page 172 of 276 ...
Page 174: ...Field Service Manual December 2003 Page 174 of 276 ...
Page 187: ...Field Service Manual December 2003 Page 187 of 276 ...
Page 216: ...Field Service Manual December 2003 Page 216 of 276 ...
Page 220: ...Field Service Manual December 2003 Page 220 of 276 Main directory structure ...
Page 225: ...Field Service Manual December 2003 Page 225 of 276 Adding a DPF file in the plotter queue ...
Page 227: ...Field Service Manual December 2003 Page 227 of 276 Stop logging ...
Page 234: ...Field Service Manual December 2003 Page 234 of 276 ...
Page 240: ...Field Service Manual December 2003 Page 240 of 276 ...
Page 242: ...Field Service Manual December 2003 Page 242 of 276 ...
Page 246: ...Field Service Manual December 2003 Page 246 of 276 ...
Page 248: ...Field Service Manual December 2003 Page 248 of 276 ...
Page 252: ...Field Service Manual December 2003 Page 252 of 276 ...
Page 268: ...Field Service Manual December 2003 Page 268 of 276 ...
Page 270: ...Field Service Manual December 2003 Page 270 of 276 ...
Page 274: ...Field Service Manual December 2003 Page 274 of 276 ...