21. Maintenance Indicators
21.2 Display Diagnosis
What info is displayed
Diagnosis
RGB-Loop: On
Panel: On
Temperature: ok
Lamp: ok
Power: ok
FPGA: ok
Cool Down: No
Fan: ok
Back
Cine VERSUM r01
Main Menu/
Installation
/
Display List
/
Display Settings
/
Diagnosis
Installation
Input Slots
File Service
Display List
Internal Pattern
When no signal
Source Transition
OSD configuration
Language
Keystone
Global Keystone:Yes
Output: [Largest]
Default Input Balance
Back
Display List
1 CV50
On
2 CV120
On
3 CV80
On
Back
Display Settings
Switch OFF
Display Info
Rename
IR Address 009
Diagnosis
Back
Cine VERSUM 50
Display Settings
Switch OFF
Display Info
Rename
IR Address 009
Diagnosis
CW Index
Orientation
Test patterns
Back
Cine VERSUM 80
Display Settings
Switch OFF
Display Info
Rename
IR Address 009
Diagnosis
Orientation
Test patterns
Lens
Lamp
Back
Cine VERSUM 120
Diagnosis
RGB-Loop: On
Panel: On
Temperature: ok
Lamps: ok
Power: ok
FPGA: ok
Cool Down: No
Fan: ok
Formatter Status
Back
Diagnosis
RGB-Loop: On
Panel: On
Temperature: ok
Lamp: ok
Power: ok
FPGA: ok
Cool Down: No
Fan: ok
Back
Formatter Status
R G B
Normal mode 1 1 1
C/P Error 0 0 0
DNLD Complete 0 0 0
System Reset 0 0 0
System Status 1 1 1
System Ready 1 1 1
RAMBUS Init 1 1 1
Back
Image 21-2
Diagnostic for Cine VERSUM Master – Cine VERSUM 80 and Cine VERSUM 120
Explanation of the items
Common for Cine VERSUM 50 – Cine VERSUM 80 and Cine VERSUM 120
RGB-Loop
On: signal loop-through enabled
Off: signal loop-through disabled
Panel
On: picture display
Off: no picture display
Temperature
OK: temperature not out of range
Lamp
OK: no lamp failure
Power
OK: no power failure
FPGA
OK: The programmable components on the deserializer board are configured.
Cool down
Yes: display in the cool down mode. Display can not be started up.
No: display not in the cool down mode. Display ready for operation.
Fan
OK: no Fan failure
For Cine VERSUM 120 only
Formatter Status
Info about the formatter board for Red, Green and Blue separately
R5976468 CINE VERSUM SYSTEM 03112003
147
Summary of Contents for R9841020 Cine VERSUM Master
Page 4: ......
Page 8: ...Table of contents 4 R5976468 CINE VERSUM SYSTEM 03112003...
Page 14: ...1 Safety Instructions 10 R5976468 CINE VERSUM SYSTEM 03112003...
Page 30: ...4 Dimensions 26 R5976468 CINE VERSUM SYSTEM 03112003...
Page 36: ...5 Location of Controls 32 R5976468 CINE VERSUM SYSTEM 03112003...
Page 48: ...6 Installation Guidelines 44 R5976468 CINE VERSUM SYSTEM 03112003...
Page 63: ...7 Connections Image 7 27 Image 7 28 Image 7 29 R5976468 CINE VERSUM SYSTEM 03112003 59...
Page 64: ...7 Connections 60 R5976468 CINE VERSUM SYSTEM 03112003...
Page 68: ...8 Operating the Remote Control 64 R5976468 CINE VERSUM SYSTEM 03112003...
Page 80: ...10 Overview GUI Menu Screens 76 R5976468 CINE VERSUM SYSTEM 03112003...
Page 84: ...11 Powering on off the Cine VERSUM System 80 R5976468 CINE VERSUM SYSTEM 03112003...
Page 88: ...12 Image Projection after Powering Up 84 R5976468 CINE VERSUM SYSTEM 03112003...
Page 92: ...13 Projection Stop Standby or Economic Standby mode 88 R5976468 CINE VERSUM SYSTEM 03112003...
Page 96: ...14 Switching linked displays To and Out Standby 92 R5976468 CINE VERSUM SYSTEM 03112003...
Page 138: ...18 Additional settings Cine VERSUM Master 134 R5976468 CINE VERSUM SYSTEM 03112003...
Page 142: ...19 Picture in Picture PIP 138 R5976468 CINE VERSUM SYSTEM 03112003...
Page 156: ...21 Maintenance Indicators 152 R5976468 CINE VERSUM SYSTEM 03112003...
Page 160: ...Index 156 R5976468 CINE VERSUM SYSTEM 03112003...