601–426 /15
F70 Series
136
Given
When
Then
CLO is enabled
No adjustment to CLO scale is
done
hasstabilized = true, even when internal
adjustment is needed to obtain the current
setpoint for the CLO
CLO is enabled
CLO scale value is being changed
hasstabilized = false, while adjusting CLO
scale
CLO is enabled
CLO scale value has been
changed
hasstabilized = true, when the CLO output has
stabilized
The hasstabilized signal can be monitored using the property:
•
illumination.clo.hasstabilized
-
"result": true
-
"result": false
•
Requires power user access
8.6.6 EWMA
EWMA
This is the average of the measurements on the light sensor, used for controlling the CLO feature.
EWMA can be monitored using the property:
•
illumination.clo.ewma
-
“result”: a value, without a defined unit
8.6.7 Setpoint
Setpoint
This feature enables the user to set the desired value directly. As no max value is given Barco recommends
using the CLO scale if different output power settings are needed when using the CLO.
The setpoint can be set and/or monitored using the property:
•
illumination.clo.setpoint
8.6.8 CLO (Light sensor) calibration
This process is only implemented for the F70 and F90 series projectors, valid from SW 2.2.
Light sensor calibration
The CLO is calibrated from the factory and re-calibration is not expected to be necessary. In the unlikely event
that the CLO would need to be re-calibrated, please log in as a Power user in Prospector and go to
Service→Light sensor calibration and follow the steps to calibrate the CLO.
8.7 IR / Night vision functionality
About
IR / Night Vision functionality is only available for the FS variant of the projector.
.
In combination with Night Vision Goggles (NVG), this will give a realistic rendering of the environment. This
will visualize in a realistic way, night time, dusk and dawn, and limited visibility scenarios.
The IR light source has a wavelength of 740nm
Summary of Contents for F70 Series
Page 1: ...ENABLING BRIGHT OUTCOMES User Manual F70 Series...
Page 10: ...601 426 15 F70 Series 10...
Page 60: ...601 426 15 F70 Series 60 Lenses Handling and features...
Page 82: ...601 426 15 F70 Series 82 Getting started...
Page 88: ...601 426 15 F70 Series 88 Source menu...
Page 162: ...601 426 15 F70 Series 162 System settings menu...
Page 166: ...601 426 15 F70 Series 166 GUI Status menu...
Page 170: ...601 426 15 F70 Series 170 3D...
Page 171: ...171 601 426 15 F70 Series 13 1 Upgrade procedure 172 Upgrade projector firmware 13...
Page 182: ...601 426 15 F70 Series 182 Technical Specifications...
Page 191: ...191 601 426 15 F70 Series C 1 DMX chart Basic 192 C 2 DMX chart Extended 193 DMX Chart C...
Page 216: ...601 426 15 F70 Series 216 Index...
Page 217: ......