R5906848 /04
DP2K SLP Series
126
2
Image 10-18
6.
Fasten the adjustment screw (reference 1 Image 11-9) which you released in step 1. Use a 5.5 mm nut driver.
When you are familiar with this adjustment procedure you can optimize the focus position by first
rotate the Integration Rod until you clearly see the sloped edges on the screen and then focusing
these edges as sharp as possible. Then rotate the Integration Rod back until the projected light
beam matches the projected outline of the DMD's. This way of focusing has to be done quickly.
Otherwise, the sealing between the DMD's and the prism will be damaged
10.12 Adjusting the Light Pipe lens No3 (zoom
lens)
Purpose of the Light Pipe zoom lens
The Light Pipe zoom lens is located inside the Light Pipe between the Integration Rod and the Fold Mirror. The
light spot upon the DMDs can be reduced or enlarged with the Light Pipe zoom lens to fit with the outline of the
DMDs.
CAUTION:
Only qualified and authorized personnel may perform this procedure.
To adjust the Light Pipe focus lens the left cover of the projector and the side cover plate of the Light
Processor compartment have to be removed.
Required tools
Nut driver 5.5 mm
How to adjust the Light Pipe zoom lens?
1.
Loosen the adjustment screw of the Light Pipe zoom lens (reference 5 Image 10-18) a few turns. Use a 5.5
mm nut driver. Do not remove the adjustment screw.
2.
Start up the projector but do not activate the light source yet.
Caution:
Projecting a light spot which is larger then the DMD outline for more then 10 seconds may
cause irreversible damage to the Sealed Light Processor. Therefor, it is important to maximum dim the
light output and adjust the light spot as quickly as possible.
3.
Set up the projector to display a
full white internal pattern
with a maximum contrast and a
maximum
dimming
. Do not activate the light source yet. Make sure that you have a 5.5 mm nut driver within reach for
the next steps.
4.
Activate the light source and zoom the projector lens in or out until the projected image is focused.
Note:
Dialog windows must be displayed sharp instead of blurry. This is independent of the focus of
the light beam.
5.
Adjust the position of the Light Pipe zoom lens by moving the adjustment screw (reference 5)
UP
or
DOWN
into a position where the light spot (reference 2) matches the projected outline (reference 3) of the DMDs upon
Summary of Contents for DP2K SLP Series
Page 1: ...ENABLING BRIGHT OUTCOMES Service Manual DP2K SLP Series ...
Page 4: ......
Page 10: ...R5906848 04 DP2K SLP Series 10 ...
Page 14: ...R5906848 04 DP2K SLP Series 14 Safety ...
Page 24: ...R5906848 04 DP2K SLP Series 24 General ...
Page 30: ...R5906848 04 DP2K SLP Series 30 Preventative maintenance actions ...
Page 38: ...R5906848 04 DP2K SLP Series 38 Mains Input ...
Page 90: ...R5906848 04 DP2K SLP Series 90 Laser Phosphor Light Source ...
Page 94: ...R5906848 04 DP2K SLP Series 94 10 Reinstall all covers Liquid cooling circuit ...
Page 138: ...R5906848 04 DP2K SLP Series 138 Light Pipe ...
Page 147: ...147 R5906848 04 DP2K SLP Series Optical alignment 12 ...
Page 150: ...R5906848 04 DP2K SLP Series 150 Optical alignment ...
Page 248: ...R5906848 04 DP2K SLP Series 248 Card Cage ...
Page 263: ...263 R5906848 04 DP2K SLP Series Exhaust system 20 ...
Page 265: ...265 R5906848 04 DP2K SLP Series Board Diagnostic LED s 21 ...
Page 270: ...R5906848 04 DP2K SLP Series 270 Board Diagnostic LED s ...
Page 290: ...R5906848 04 DP2K SLP Series 290 Dust Filters ...
Page 294: ...R5906848 04 DP2K SLP Series 294 Troubleshooting ...
Page 382: ...R5906848 04 DP2K SLP Series 382 Troubleshooting ...
Page 394: ...R5906848 04 DP2K SLP Series 394 Projector cleaning ...
Page 395: ...395 Overview Hazards R5906848 04 DP2K SLP Series Appendix A ...
Page 409: ...R5906848 04 DP2K SLP Series 409 ...