R5906848 /04
DP2K SLP Series
323
Code 5351:
“
smps primary heatsink - temperature high
”
(Warning)
Situation
Solution
Ambient temperature too high.
Check the ambient temperature at the air inlets of the projector. Make sure
that the ambient temperature does not exceed 35°C (95°F).
Blocked large dust filter.
Clean the large dust filter or replace with new one. See service manual
chapter
“
Malfunction air extraction
system.
Check the condition of the air extraction system. The air extraction system
must be capable of removing minimum 4 m³/min (140 CFM) per installed
DP2K-SLP Series digital projector.
Note:
limit the amount of extraction to a maximum of 5m
3
/min (180 CFM).
Excessive air extraction can dramatically speed-up contamination of the
projector air inlet filters, hence requiring more regular filter cleaning
interventions.
Malfunction SMPS board.
Replace the SMPS module. See service manual chapter
“
”
, page 39.
Malfunction Cinema Control
board.
Replace the Cinema Control board. See service manual chapter
Replacement of the Cinema Controller
Code 5361:
“
smps secundary heatsink - temperature high
”
(Warning)
Situation
Solution
Ambient temperature too high.
Check the ambient temperature at the air inlets of the projector. Make sure
that the ambient temperature does not exceed 35°C (95°F).
Blocked large dust filter.
Clean the large dust filter or replace with new one. See service manual
chapter
“
Malfunction air extraction
system.
Check the condition of the air extraction system. The air extraction system
must be capable of removing minimum 4 m³/min (140 CFM) per installed
DP2K-SLP Series digital projector.
Note:
limit the amount of extraction to a maximum of 5m
3
/min (180 CFM).
Excessive air extraction can dramatically speed-up contamination of the
projector air inlet filters, hence requiring more regular filter cleaning
interventions.
Malfunction SMPS board.
Replace the SMPS module. See service manual chapter
“
”
, page 39.
Malfunction Cinema Control
board.
Replace the Cinema Control board. See service manual chapter
Replacement of the Cinema Controller
Code 5364:
“
smps secundary heatsink - temperature sensor open
”
(Error)
Situation
Solution
Malfunction SMPS board.
Replace the SMPS module. See service manual chapter
“
”
, page 39.
Code 5365:
“
smps secundary heatsink - temperature sensor short
”
(Error)
Situation
Solution
Malfunction SMPS board.
Replace the SMPS board. See service manual chapter
”
, page 39.
Summary of Contents for DP2K SLP Series
Page 1: ...ENABLING BRIGHT OUTCOMES Service Manual DP2K SLP Series ...
Page 4: ......
Page 10: ...R5906848 04 DP2K SLP Series 10 ...
Page 14: ...R5906848 04 DP2K SLP Series 14 Safety ...
Page 24: ...R5906848 04 DP2K SLP Series 24 General ...
Page 30: ...R5906848 04 DP2K SLP Series 30 Preventative maintenance actions ...
Page 38: ...R5906848 04 DP2K SLP Series 38 Mains Input ...
Page 90: ...R5906848 04 DP2K SLP Series 90 Laser Phosphor Light Source ...
Page 94: ...R5906848 04 DP2K SLP Series 94 10 Reinstall all covers Liquid cooling circuit ...
Page 138: ...R5906848 04 DP2K SLP Series 138 Light Pipe ...
Page 147: ...147 R5906848 04 DP2K SLP Series Optical alignment 12 ...
Page 150: ...R5906848 04 DP2K SLP Series 150 Optical alignment ...
Page 248: ...R5906848 04 DP2K SLP Series 248 Card Cage ...
Page 263: ...263 R5906848 04 DP2K SLP Series Exhaust system 20 ...
Page 265: ...265 R5906848 04 DP2K SLP Series Board Diagnostic LED s 21 ...
Page 270: ...R5906848 04 DP2K SLP Series 270 Board Diagnostic LED s ...
Page 290: ...R5906848 04 DP2K SLP Series 290 Dust Filters ...
Page 294: ...R5906848 04 DP2K SLP Series 294 Troubleshooting ...
Page 382: ...R5906848 04 DP2K SLP Series 382 Troubleshooting ...
Page 394: ...R5906848 04 DP2K SLP Series 394 Projector cleaning ...
Page 395: ...395 Overview Hazards R5906848 04 DP2K SLP Series Appendix A ...
Page 409: ...R5906848 04 DP2K SLP Series 409 ...