R5906848 /04
DP2K SLP Series
363
Code 20394:
“
LCB
–
36V phosphor wheel voltage too low
”
Situation
Solution
Bad wiring connection
Check connector J901 on the LCB and the LPM. Make sure the cable is
properly seated. If problem persists, replace the cable.
Def36V module LPM
Replace the +36V module in the LDM (slot 6). See service procedure
Replacing a Laser Drive Module
”
, page 56.
Malfunction LCB.
Replace the Laser Control Board (LCB). See service procedure
”
, page 64.
Code 20397:
“
LCB
–
36V phosphor wheel voltage too high
”
Situation
Solution
Malfunction LCB.
Replace the Laser Control Board (LCB). See service procedure
”
, page 64.
Code 20401:
“
LDM 1-6
–
Heatsink rectifier temperature too high
”
For this error the same troubleshooting table can be applied to as for code
20377
:
“
LDM 1-2
–
Heatsink
rectifier temperature too high
”
.
Code 20402:
“
LDM 1-6
–
Heatsink rectifier temperature sensor shorted
”
For this error the same troubleshooting table can be applied to as for code
20378
:
“
LDM 1-2
–
Heatsink
rectifier temperature sensor shorted
”
.
Code 20403:
“
LDM 1-6
–
Heatsink rectifier temperature sensor open
”
For this error the same troubleshooting table can be applied to as for code
20379
:
“
LDM 1-2
–
Heatsink
rectifier temperature sensor open
”
.
Code 20407:
“
LDM 1-6
–
Heatsink drain temperature too high
”
For this error the same troubleshooting table can be applied to as for code
20377
:
“
LDM 1-2
–
Heatsink
rectifier temperature too high
”
.
Code 20408:
“
LDM 1-6
–
Heatsink drain temperature sensor shorted
”
For this error the same troubleshooting table can be applied to as for code
20378
:
“
LDM 1-2
–
Heatsink
rectifier temperature sensor shorted
”
.
Code 20409:
“
LDM 1-6
–
Heatsink drain temperature sensor open
”
For this error the same troubleshooting table can be applied to as for code
20379
:
“
LDM 1-2
–
Heatsink
rectifier temperature sensor open
”
.
Code 20412:
“
LDM 1-6
–
Not configured (invalid module type)
”
For this error the same troubleshooting table can be applied to as for code
20278
:
“
LDM 1
–
Not configured
(invalid module type)
”
.
Code 20413:
“
LDM 1-6
–
Not configured (no communication)
”
Situation
Solution
Mismatch in Laser Power
Modules
Check if the +36 V module is in the correct slot (LDM slot 6).
Summary of Contents for DP2K SLP Series
Page 1: ...ENABLING BRIGHT OUTCOMES Service Manual DP2K SLP Series ...
Page 4: ......
Page 10: ...R5906848 04 DP2K SLP Series 10 ...
Page 14: ...R5906848 04 DP2K SLP Series 14 Safety ...
Page 24: ...R5906848 04 DP2K SLP Series 24 General ...
Page 30: ...R5906848 04 DP2K SLP Series 30 Preventative maintenance actions ...
Page 38: ...R5906848 04 DP2K SLP Series 38 Mains Input ...
Page 90: ...R5906848 04 DP2K SLP Series 90 Laser Phosphor Light Source ...
Page 94: ...R5906848 04 DP2K SLP Series 94 10 Reinstall all covers Liquid cooling circuit ...
Page 138: ...R5906848 04 DP2K SLP Series 138 Light Pipe ...
Page 147: ...147 R5906848 04 DP2K SLP Series Optical alignment 12 ...
Page 150: ...R5906848 04 DP2K SLP Series 150 Optical alignment ...
Page 248: ...R5906848 04 DP2K SLP Series 248 Card Cage ...
Page 263: ...263 R5906848 04 DP2K SLP Series Exhaust system 20 ...
Page 265: ...265 R5906848 04 DP2K SLP Series Board Diagnostic LED s 21 ...
Page 270: ...R5906848 04 DP2K SLP Series 270 Board Diagnostic LED s ...
Page 290: ...R5906848 04 DP2K SLP Series 290 Dust Filters ...
Page 294: ...R5906848 04 DP2K SLP Series 294 Troubleshooting ...
Page 382: ...R5906848 04 DP2K SLP Series 382 Troubleshooting ...
Page 394: ...R5906848 04 DP2K SLP Series 394 Projector cleaning ...
Page 395: ...395 Overview Hazards R5906848 04 DP2K SLP Series Appendix A ...
Page 409: ...R5906848 04 DP2K SLP Series 409 ...