R5906848 /04
DP2K SLP Series
368
Code 21113:
“
LDM 1-2
–
LLS bank 1 drain power too high
”
Situation
Solution
This error appears together
with a blue taillight on the
projector.
There will be an impact on the performance, although not noticeable.
In order to bring the projector back to DCI color spec, perform the
following actions:
•
Use Communicator to block all bad laser banks.
•
Perform a full color calibration.
For more info, see Communicator User manual.
This error appears together
with a yellow taillight on the
projector.
There will be a noticeable impact on color performance and/or brightness.
The projector will still play, but will probably no longer play within the DCI
specifications.
Replace the light source. See service procedure
“
, page 59.
This error appears together
with a red taillight on the
projector
Projector will shut down / no longer start up, until sufficient service actions
have been taken.
Replace the light source. See service procedure
“
, page 59.
Code 21117:
“
LDM 1-2
–
LLS bank 2 drain power too high
”
For this error the same troubleshooting table can be applied to as for code
21113
:
“
LDM 1-2
–
LLS bank 1
drain power too high
”
.
Code 21121:
“
LDM 1-2
–
LLS bank 3 drain power too high
”
For this error the same troubleshooting table can be applied to as for code
21113
:
“
LDM 1-2
–
LLS bank 1
drain power too high
”
.
Code 21125:
“
LDM 1-3
–
LLS bank 4 drain power too high
”
For this error the same troubleshooting table can be applied to as for code
21113
:
“
LDM 1-2
–
LLS bank 1
drain power too high
”
.
Code 21129:
“
LDM 1-3
–
lls bank 5 drain power too high
”
Situation
Solution
Problem on mixed laser bank.
Laser bank will shut down
Replace the light source. See service procedure
“
, page 59.
Code 21133:
“
LDM 1-3
–
lls bank 6 drain power too high
”
Situation
Solution
Problem on blue laser bank.
Laser bank will shut down
Replace the light source. See service procedure
“
, page 59.
Code 21137:
“
LDM 1-4
–
LLS bank 7 drain power too high
”
For this error the same troubleshooting table can be applied to as for code
21133
:
“
LDM 1-3
–
LLS bank 6
drain power too high
”
.
Code 21141:
“
LDM 1-4
–
LLS bank 8 drain power too high
”
For this error the same troubleshooting table can be applied to as for code
21129
:
“
LDM 1-3
–
LLS bank 5
drain power too high
”
.
Summary of Contents for DP2K SLP Series
Page 1: ...ENABLING BRIGHT OUTCOMES Service Manual DP2K SLP Series ...
Page 4: ......
Page 10: ...R5906848 04 DP2K SLP Series 10 ...
Page 14: ...R5906848 04 DP2K SLP Series 14 Safety ...
Page 24: ...R5906848 04 DP2K SLP Series 24 General ...
Page 30: ...R5906848 04 DP2K SLP Series 30 Preventative maintenance actions ...
Page 38: ...R5906848 04 DP2K SLP Series 38 Mains Input ...
Page 90: ...R5906848 04 DP2K SLP Series 90 Laser Phosphor Light Source ...
Page 94: ...R5906848 04 DP2K SLP Series 94 10 Reinstall all covers Liquid cooling circuit ...
Page 138: ...R5906848 04 DP2K SLP Series 138 Light Pipe ...
Page 147: ...147 R5906848 04 DP2K SLP Series Optical alignment 12 ...
Page 150: ...R5906848 04 DP2K SLP Series 150 Optical alignment ...
Page 248: ...R5906848 04 DP2K SLP Series 248 Card Cage ...
Page 263: ...263 R5906848 04 DP2K SLP Series Exhaust system 20 ...
Page 265: ...265 R5906848 04 DP2K SLP Series Board Diagnostic LED s 21 ...
Page 270: ...R5906848 04 DP2K SLP Series 270 Board Diagnostic LED s ...
Page 290: ...R5906848 04 DP2K SLP Series 290 Dust Filters ...
Page 294: ...R5906848 04 DP2K SLP Series 294 Troubleshooting ...
Page 382: ...R5906848 04 DP2K SLP Series 382 Troubleshooting ...
Page 394: ...R5906848 04 DP2K SLP Series 394 Projector cleaning ...
Page 395: ...395 Overview Hazards R5906848 04 DP2K SLP Series Appendix A ...
Page 409: ...R5906848 04 DP2K SLP Series 409 ...