R5906848 /04
DP2K SLP Series
366
Code 20577:
“
LDM 1-3
–
Heatsink rectifier temperature too high
”
For this error the same troubleshooting table can be applied to as for code
20377
:
“
LDM 1-2
–
Heatsink
rectifier temperature too high
”
.
Code 20578:
“
LDM 1-3
–
Heatsink rectifier temperature sensor shorted
”
For this error the same troubleshooting table can be applied to as for code
20378
:
“
LDM 1-2
–
Heatsink
rectifier temperature sensor shorted
”
.
Code 20579:
“
LDM 1-3
–
Heatsink rectifier temperature sensor open
”
For this error the same troubleshooting table can be applied to as for code
20379
:
“
LDM 1-2
–
Heatsink
rectifier temperature sensor open
”
.
Code 20583:
“
LDM 1-3
–
Heatsink drain temperature too high
”
For this error the same troubleshooting table can be applied to as for code
20377
:
“
LDM 1-2
–
Heatsink
rectifier temperature too high
”
.
Code 20584:
“
LDM 1-3
–
Heatsink drain temperature sensor shorted
”
For this error the same troubleshooting table can be applied to as for code
20378
:
“
LDM 1-2
–
Heatsink
rectifier temperature sensor shorted
”
.
Code 20585:
“
LDM 1-3
–
Heatsink drain temperature sensor open
”
For this error the same troubleshooting table can be applied to as for code
20379
:
“
LDM 1-2
–
Heatsink
rectifier temperature sensor open
”
.
Code 20609:
“
LDM 1-4
–
LLS bank 7 drain voltage too high
”
For this error the same troubleshooting table can be applied to as for code
20323
:
“
LDM 1-2
–
LLS bank 1
drain voltage too high
”
.
Code 20613:
“
LDM 1-4
–
LLS bank 8 drain voltage too high
”
For this error the same troubleshooting table can be applied to as for code
20323
:
“
LDM 1-2
–
LLS bank 1
drain voltage too high
”
.
Code 20621:
“
LDM 1-4
–
LLS bank 7 current too high
”
For this error the same troubleshooting table can be applied to as for code
20335
:
“
LDM 1-2
–
LLS bank 1
current too high
”
.
Code 20625:
“
LDM 1-4
–
LLS bank 8 current too high
”
For this error the same troubleshooting table can be applied to as for code
20335
:
“
LDM 1-2
–
LLS bank 1
current too high
”
.
Code 20645:
“
LDM 1-4
–
LLS bank 7 temperature too high
”
For this error the same troubleshooting table can be applied to as for code
20359
:
“
LDM 1-2
–
LLS bank 1
temperature too high
”
.
Code 20646:
“
LDM 1-4
–
LLS bank 7 temperature sensor shorted
”
For this error the same troubleshooting table can be applied to as for code
20360
:
“
LDM 1-2
–
LLS bank 1
temperature sensor shorted
”
.
Code 20647:
“
LDM 1-4
–
LLS bank 7 temperature sensor open
”
For this error the same troubleshooting table can be applied to as for code
20361
:
“
LDM 1-2
–
LLS bank 1
temperature sensor open
”
.
Summary of Contents for DP2K SLP Series
Page 1: ...ENABLING BRIGHT OUTCOMES Service Manual DP2K SLP Series ...
Page 4: ......
Page 10: ...R5906848 04 DP2K SLP Series 10 ...
Page 14: ...R5906848 04 DP2K SLP Series 14 Safety ...
Page 24: ...R5906848 04 DP2K SLP Series 24 General ...
Page 30: ...R5906848 04 DP2K SLP Series 30 Preventative maintenance actions ...
Page 38: ...R5906848 04 DP2K SLP Series 38 Mains Input ...
Page 90: ...R5906848 04 DP2K SLP Series 90 Laser Phosphor Light Source ...
Page 94: ...R5906848 04 DP2K SLP Series 94 10 Reinstall all covers Liquid cooling circuit ...
Page 138: ...R5906848 04 DP2K SLP Series 138 Light Pipe ...
Page 147: ...147 R5906848 04 DP2K SLP Series Optical alignment 12 ...
Page 150: ...R5906848 04 DP2K SLP Series 150 Optical alignment ...
Page 248: ...R5906848 04 DP2K SLP Series 248 Card Cage ...
Page 263: ...263 R5906848 04 DP2K SLP Series Exhaust system 20 ...
Page 265: ...265 R5906848 04 DP2K SLP Series Board Diagnostic LED s 21 ...
Page 270: ...R5906848 04 DP2K SLP Series 270 Board Diagnostic LED s ...
Page 290: ...R5906848 04 DP2K SLP Series 290 Dust Filters ...
Page 294: ...R5906848 04 DP2K SLP Series 294 Troubleshooting ...
Page 382: ...R5906848 04 DP2K SLP Series 382 Troubleshooting ...
Page 394: ...R5906848 04 DP2K SLP Series 394 Projector cleaning ...
Page 395: ...395 Overview Hazards R5906848 04 DP2K SLP Series Appendix A ...
Page 409: ...R5906848 04 DP2K SLP Series 409 ...