Using the Setup Menu
•
When sampling is set to
OverSample
, values represent the oversampling factor
being used.
For all
Horizontal
“active area” fields, all units are measured in pixels:
•
H Total
— adjusts the total pixel count per line. This value cannot be adjusted if
the input type is
DVI
/
SDI
.
•
H Position
— adjusts the offset of start of active area from H sync.
•
H Active
— sets the size of the active area.
For all
Vertical
“active area” fields, all unit are measured in lines.
•
V Total
— indicates the total line count per frame. This value is measured, and
can never be adjusted. Its value will always be shown in brackets.
•
V Position
— sets the offset of start of active area from V sync.
•
V Active
— sets the size of the active area.
^ÇàìëíáåÖ=p~ãéäÉ=mÜ~ëÉ
The DCS-200 has two A-to-D converters, which are referred to as
A
and
B
in the
Timing
Adjust Menu
. The sample phase value of each scaler is initially filled in by the
Auto
Config
command, or set to the default value of
0
(zero). If required, advanced users can
fine-tune the image by adjusting the sample clock phase of each scaler directly —
but only
for inputs whose “type” is analog
.
•
Adjustment range
: -16 to 15
•
Default
: 0
Use the following steps to adjust sample clock phase of each scaler, for inputs whose
“type” is analog.
1.
From the
Input Menu
, navigate to the
Timing Adjust Menu
, and scroll to the
Phase A
or
Phase B
line.
2.
In the
Inputs Section
, select an input whose “type” is analog.
3. TAKE
the input to Program. The button lights solid.
4.
Pend the
same input
for the next transition. In this mode, only one button will now
be lit solid, and no buttons will be blinking.
5.
On the
Timing Adjust Menu
, note that one of the two
Phase
lines will be
bracketed, and the other will be unbracketed. When you press
TAKE
, the
brackets will switch positions. The un-bracketed line is the active scaler.
Figure 4-25.
Timing Adjust Menu, phase indication of active scaler
6.
On the selected input, put up a
Burst
pattern. For example, if the source is a
computer, use a program such as
DisplayMate
®
to generate the pattern.
7.
Scroll to the unbracketed
Phase
line, and press
SEL
.
8.
Use the
Adjust
knob to tweak the burst pattern for the maximum visual clarity and
a minimum amount of visual noise, then press
SEL
to accept the new value.
T I M I N G A D J U S T
S a m p l i n g
1 : 1
> P h a s e A
0
P h a s e B
[ 0 ]