3. Getting started
Barco – Argus X Terminal – DOC-3265-2 – user's manual – Revision 06 – February-2005
___________________________________________________________________
3-26
Connecting order remote power on/off and genlock
In general all O
MNI
B
US
devices that are locked to the same source must be connected to each other by means of
the
remote power on/off
cabling.
Therefore in a distributed system an additional connection is necessary; the
remote power on/off
connector
[16] on the back of the central processor must be connected with
external genlock loop through in
connector
[15] on the back of the first rendering processor.
The
remote power on/off out
connector of the last O
MNI
B
US
must be connected to the
external genlock loop through in
connector [15] on the back of the next rendering
processor.
If multiple A
RGUS
systems shall be locked to the same source, the
remote power on/off out
connector of the
last O
MNI
B
US
must be connected to the
external genlock loop through in
connector [15] on the back of the
central processor of the next A
RGUS
system.
If an external source is used for genlocking it must be connected to the
external genlock in
connector [17] on
the back of the A
RGUS
P
ROCESSOR
.
An example of cabling for an external genlock source is given in the figure below:
external
genlock
A
RGUS
System 1
A
RGUS
System 2
Central Processor
Central Processor
Rendering 1
Rendering 1
Rendering 2
Rendering 2
Figure 3-35
cabling for remote power on/off and external genlock