![background image](http://html1.mh-extra.com/html/barco/argus-x-terminal/argus-x-terminal_user-manual_3822608028.webp)
3. Getting started
Barco – Argus X Terminal – DOC-3265-2 – user's manual – Revision 06 – February-2005
___________________________________________________________________
3-10
3.2.4
Keyboard extension
The keyboard extension allows a distant positioning of keyboard and mouse. The figure below shows schemati-
cally the parts and the cabling of the keyboard extension.
The keyboard extension is made up of two extension boxes (
remote extension box REX
[3],
local extension
box LEX
[5]) and two connection cables
(connection cable 20m
[4],
PC cable
[6 ]). Keyboard and mouse are
plugged into the
remote extension box
instead of being plugged directly into the P
ROCESSOR
. The
remote
extension box
is connected to the
local extension box
with the
connection cable 20m
.
The
local extension box
is connected to the
PS/2 keyboard
and
PS/2 mouse
port of the P
ROCESSOR
with the
PC
cable
, which has on the one end a single plug, but on the other end two plugs.
The two interface boxes are prepared for grounding. On each side labeled
EXT
there is a thread for fixing a ring
connector size 3.
1
mouse
2
keyboard
3
remote extension box
TAS-3196
4
connection cable 20m
TAS-2710
5
local extension box
TAS-3195
6
PC cable
TAS-3201
7
P
ROCESSOR
8
grounding
Figure 3-12
keyboard extension