3. Getting started
Barco – Argus X Terminal – DOC-3265-2 – user's manual – Revision 06 – February-2005
_____________________________________________________________________
3-3
On the left side there are the air supply openings [1]. In the center of the standard case there are three buttons.
The upper one is the
restart
button [3], the one in the middle is the
lock keyboard switch
[4], that serves to
enable or disable keyboard input and the lower one is the
power
button [13]. The two LEDs next to the switches
indicate
hard disk drive operating
[7] respectively
power on
[8].
The case for redundant operation additionally has a
buzzer reset button
for power module failure [5], which is
located on the top leftmost position. The
restart button
[3] is located between the
lock keyboard switch
[4]
and the
power button
[13] instead. On the front there is also an additional LED, indicating
power module
failure
[6].
On the right hand side there is the floppy disk drive [9], followed by the CD ROM drive [11] and below it the hard
disk drive [10a] or [10b].
The RAID hard disk drive system [10b] is available for RAID 1 (as shown in
Figure 3-1 front view of Argus Processor
for RAID 5, please see the figure below.
Figure 3-2
RAID 5 hard disk drivers
Each RAID 5 hard disk provides three LED’s at the front of the removable frame. If the red LED lightens, this indi-
cates that this particular hard disk has failed and should be replaced.
Please note for RAID 5 systems:
Never remove more than one hard disk while the system is running. Otherwise the system
will crash and not be able to restore!
A hard disk is already switched off by turning the frame lock key!
Never change the sequential order of the hard disks. Otherwise the complete data on the
drives will get corrupt and not be able to restore!
The rendering processors of the distributed system are assembled accordingly. They are
delivered without CD-ROM drive and hard disk drive.