ENERGA 80-50
• Remove the retardant plate by tilting it upwards slightly, sliding it backwards and
removing it diagonally to one side.
(Original position of retardant plate is between the 4 spacers.)
7.7
REPLACING THE PARTICULATE FILTER
• Remove the holder from the appliance
• Remove the top of the holder.
(see Chapter 7.6).
• Remove the particulate fi lter (ceramic stone) and fi t the new fi lter.
• Place the top plate into the holder again and fi t the holder in the appliance,
following the above steps in reverse order.
Note !
Replace the top of the holder properly.
Otherwise, the holder will no longer
fi t into the appliance.