14
ENERGA 80-50
• Check the operation and setting of the fl ue gas fl ap and the particulate fi lter.
Locking slider all the way to the left (closed):
Flue gas fl ap operation works normally:
Door open
Pin comes forwards
Flue gas fl ap open
Door closed
Pin is pressed in by the door
Flue gas fl ap closed
Locking slider all the way to the right (open):
Flue gas fl ap always remains open !!
Pin for fl ue gas fl ap
Locking slider (inside door)
Combustion air-supply slider
• Flue gas fl ap in “open” position.