38
ENERGA 80-50
• Fit the lower air slide using a long bolt, to lift this slide temporarily upwards during the
installation.
• Check the operation of the fan set.
Note !
:
The fan set should be connected to an earthed wall socket.
This socket must remain accessible at all times.
The electrical connection must be undertaken by a qualifi ed professional.
• Fit/place all components back in the appliance in the reverse order to above.
The fan is at all times accessible via the fi re for service purposes.
By means of the hollow area and the openings at the front or on both sides of the chim-
ney breast, the fan system will extract suffi cient air from the room to be heated for the
convection box of the fi re.