3.2 Sensor Menu (MENU)
Access the Sensor Menu by pressing Enter
from Run mode, when MENU is displayed. The Sensor Menu includes
several submenus that provide access to view and change sensor settings and to view sensor information.
MENU D1_OUT
Access discrete 1 output settings
MENU INPUT
Select input line settings (remote TEACH, etc.)
MENU MEASURE
Select response speed
MENU DISPLAY
Select display units and orientation
MENU INFO
View sensor information
MENU RESET
Reset to factory defaults
Sensor Menu
Run
Mode
(See Sensor Menu Full Map for the complete map)
or
or
Go Back to Parent Menu
Select Menu Item
Press to Save Setting
Press and Hold to Go Back
to Run Mode
MENU D2_OUT
Access discrete 2 output settings
Figure 14. Sensor Menu Basic Map
See Sensor Menu Full Map and the Menu sections of this manual for more information.
3.3 Remote Input
Use the remote input to program the sensor remotely. The remote input provides limited programming options.
To use the Active High function, connect the gray input wire to V+ (12 to 30 V dc). Pulse the remote input according to the
diagram and the instructions provided in this manual.
The length of the individual programming pulses is equal to the value T: 0.04 seconds
≤
T
≤
0.8 seconds.
Exit remote programming modes by holding the remote input low for > 2 seconds, or waiting for the automatic 60-second
timeout, or by pressing and holding Escape
for 2 seconds. The sensor returns to Run mode without saving any new
settings.