Method
Action
Result
Remote Input
(Sets A_OUT
and D_OUT
window Size)
Pulse the remote input 1 to 6 times to select the desired window
size.
Window Size
Pulses
LE250
LE550
1
1 mm
10 mm
2
10 mm
50 mm
3
50 mm
100 mm
4
100 mm
300 mm
5
150 mm
500 mm
6
250 mm
800 mm
The new value flashes and the sensor
returns to Run mode.
TEACH Midpoint
The TchMdPt option sets the midpoint that determines the actual measurement window.
Navigate: MENU > Dx_OUT > TchMid > TchMdPt
Remote Input: Available
Button Instructions
1. Present the target.
Action
Result
Present the target.
The target's distance measurement value
displays.
2. Access the TEACH midpoint mode and TEACH the sensor.
Action
Result
Navigate: MENU > Dx_OUT > TchMid > TchMdPt
"TchMdPt Teaching" displays while the
sensor is being taught.
TEACH Accepted
The new value is shown on the second line
of the display and flashes before it is saved
and the sensor returns to "TchMid
TchMdPt".
TEACH Not Accepted
"FAIL" and a warning message display, and
the sensor returns to "TchMid TchMdPt".
Remote Input Instructions
1. Access the TEACH mode.
Action
Result
Single-pulse the remote input.
T
"RMT TCH" and the current measurement
value display.
2. Present the target.
Action
Result
Present the target.
"RMT TCH" and the target's measurement
value display.
3. TEACH the sensor.
L-GAGE
®
LE250/550 IO-Link Laser Gauging Sensors
16