Navigate: MENU > INPUT > Type
Remote Input: Not available
Default: Disabled
Input Type
Description
Teach
The remote input is used to TEACH and program the sensor. (Default)
LasrEnbl
The remote input is used to control when the laser emitter is On/Off.
SyncMstr
The remote input is used as the Master Sync output to an attached Slave sensor (see
on page 26).
SyncSlve
The remote input is used as the Slave Sync input from an attached Master sensor (see
on page 26).
Disabled
The remote input is disabled.
3.7 Measure Menu (MEASURE)
Use this menu to view or change the:
•
Speed
or
or
Go Back to Parent Menu
Select Menu Item
Press to Save Setting
Press and Hold to Go Back
to Run Mode
Default Setting
MENU MEASURE
Speed Standard
Speed Fast
Speed Medium
Speed Slow
MEASURE Speed
Figure 20. Measure Menu Map
3.7.1 Speed
The Speed option sets the speed at which the measurement is calculated. This process uses averaging in the digital
processing of the signal to calculate the measurement. A slower speed increases the response time of the sensor but
improves the repeatability. See
on page 30 for repeatability specifications for each speed.
Navigate: MENU > MEASURE > Speed
Remote Input: Not available
Default: Standard
Class 1 Laser Models
Class 2 Laser Models
Speed
Response Time
Response Time in Sync
Mode
Response Time
Response Time in Sync
Mode
Fast
2 ms
4 ms
2 ms
4 ms
Standard
10 ms (default)
20 ms
5 ms (default)
10 ms
Medium
30 ms
60 ms
15 ms
30 ms
Slow
100 ms
200 ms
50 ms
100 ms
L-GAGE
®
LE250/550 IO-Link Laser Gauging Sensors
22
www.bannerengineering.com - Tel: 763.544.3164