Table 1: Window Size (WndSize)
Variable
LE250 Models
LE550 Models
X1
1 mm
10 mm
X2
10 mm
50 mm
X3
50 mm
100 mm
Variable
LE250 Models
LE550 Models
X4
100 mm
300 mm
X5
150 mm
500 mm
X6
250 mm
800 mm
3.4 Locking and Unlocking the Sensor
Use the lock and unlock feature to prevent unauthorized or accidental programming changes. A lock symbol
displays in
the upper left corner of the display to indicate when the sensor is locked. When locked, the menus are available to view
settings, but the values cannot be changed. The remote input is also disabled, except for the unlock function.
Button Instructions
To lock or unlock the sensor using the buttons, press and hold Down
and Escape
simultaneously for 3 seconds.
Remote Input Instructions
1. Access the setup mode.
Action
Result
Double-pulse the remote input.
T
T
T
"REMOTE SETUP" displays.
2. Access the lock/unlock function.
Action
Result
Four-pulse the remote input.
T
T
T
T
T
T
T
"LOCK" and the current status (unlocked or
locked) display.
3. Lock or unlock the sensor.
Action
Result
Unlock : Single-pulse the remote line.
T
"Unlocked" flashes and the sensor returns
to Run mode. The sensor is unlocked.
Lock: Double-pulse the remote input.
T
T
T
"Locked" flashes and the sensor returns to
Run mode. The sensor is locked and the
lock symbol displays in the upper left
corner.