5 Additional Remote TEACH Procedures
5.1 TEACH Both Discrete Output Switch Points Together
Use the following procedure to teach both Discrete Output switch points at the same time using the remote input. This
feature is not available using the buttons.
1. Access the TEACH mode.
Action
Result
Single-pulse the remote input.
T
"RMT TCH" and the current measurement
value display.
2. Present the target.
Action
Result
Present the switch point one target.
"RMT TCH"and the target's measurement
value display.
3. TEACH the sensor.
Action
Result
Three-pulse the remote input.
T
T
T
T
T
"D1D2Spt1 Teaching" displays while the
sensor is being taught.
TEACH Accepted
The new value displays on the second line
of the display, flashes, and then
"D1D2Spt2" and the current measurement
value display.
TEACH Not Accepted
"FAIL" flashes, the sensor returns to step
2, and "RMT TCH" displays.
4. Present the target.
Action
Result
Present the switch point two target.
"D1D2Spt2" and the target's measurement
value display.
5. TEACH the sensor.
Action
Result
Single-pulse the remote input.
T
"D1D2Spt2 Teaching" displays while the
sensor is being taught.
TEACH Accepted
The new value displays on the second line
of the display, flashes, and the sensor
returns to Run mode.
TEACH Not Accepted
"FAIL" flashes, the sensor returns to step
2, and "RMT TCH" displays.
5.2 TEACH Both Discrete Output Midpoints Together
Use the following procedure to teach an identical discrete output midpoint (switch point) for both D1_OUT and D2_OUT at
the same time using the remote input. This feature is not available using the buttons. Note that if the window sizes were
set independently (using the buttons), the windows taught using the following procedure could be different.
1. Access the TEACH mode.
L-GAGE
®
LE250/550 IO-Link Laser Gauging Sensors
www.bannerengineering.com - Tel: 763.544.3164
27