ProductChange Command Group
Command
Group
Item
Description
Do
ProductChange
[
Name]
Forces the device to switch to the specified inspection. The device does
not transmit a response until it has completed the action. Inspections
results will be invalid until the next trigger.
Get
ProductChange
InspectionNames
List of all inspections stored in the device.
Examples
>>
get productchange inspectionnames
\x0D\x0A
<<
OK\x0D\x0A
>>
do productchange "inspection2"
\x0D\x0A
<<
OK\x0D\x0A
History Command Group
Command
Group
Item
Description
Get
History
Passed
Indicates the number of passed inspections for the active inspection.
This value is cleared (reset) whenever history is cleared. This value is
cleared (reset) when the device starts up or is rebooted.
Get
History
Failed
Indicates the number of failed inspections for the active inspection. This
value is cleared (reset) whenever history is cleared. This value is cleared
(reset) when the device starts up or is rebooted.
Get
History
MissedTriggers
Indicates the number of missed triggers for the active inspection. This
value is cleared (reset) whenever history is cleared. This value is cleared
(reset) when the device starts up or is rebooted.
Get
History
StartFrameNumber
Indicates the starting frame number for the active inspection. This value
is cleared (reset) whenever history is cleared. This value is cleared (reset)
when the device starts up or is rebooted.
Get
History
EndFrameNumber
Indicates the latest frame number for the active inspection. This value is
cleared (reset) whenever history is cleared. This value is cleared (reset)
when the device starts up or is rebooted.
Get
History
TotalFrames
Indicates the total number inspections (frames) for the active inspection.
This value is cleared (reset) whenever history is cleared. This value is
cleared (reset) when the device starts up or is rebooted.
Get
History
MinInspectionTime
Indicates the minimum (fastest) inspection time for the active inspection.
This value is cleared (reset) whenever history is cleared. This value is
cleared (reset) when the device starts up or is rebooted.
Get
History
MaxInspectionTime
Indicates the maximum (slowest) inspection time for the active
inspection. This value is cleared (reset) whenever history is cleared. This
value is cleared (reset) when the device starts up or is rebooted.
Get
History
MinBarcodeCount
Indicates the minimum number of barcodes read for the active
inspection This value is cleared (reset) whenever history is cleared. This
value is cleared (reset) when the device starts up or is rebooted.
Get
History
MaxBarcodeCount
Indicates the maximum number of barcodes read for the active
inspection This value is cleared (reset) whenever history is cleared. This
value is cleared (reset) when the device starts up or is rebooted.
Do
History
Clear
Clears all history fields for the active inspection. History values include
pass count, fail count, execution times and sensor specific history
values. This command can be performed using the sensor's
touchscreen.