Table 22: PCCC PLC Input Registers (iVu BCR Outputs, N7 Table)
WORD #
WORD NAME
DATA TYPE
0
Input Bits ACK Register (see
16-bit integer
1
16-bit integer
2-3
Error Code
32-bit integer
4-5
Inspection Number
32-bit integer
6-7
Iteration Count
32-bit integer
8-9
Pass Count
32-bit integer
10-11
Fail Count
32-bit integer
12-13
Missed Triggers
32-bit integer
14-15
Current Inspection Time
Float
16
Sensor Pass/Fail Coil
16-bit integer
17-29
reserved
16-bit integer
30-52
Inspection Name
2-Word 20 Unicode characters
53-54
Frame Number
32-bit integer
55
Sensor Type ID
16-bit integer
56
Barcode Count
16-bit integer
57
Barcode-1 Type
16-bit integer
58
Barcode-1 Actual Decoded Data Length
16-bit integer
59-60
Barcode-1 Data Array Length
32-bit integer
61-162
Barcode-1 Data Array
100 Byte Array
163-170
reserved
16-bit integer
171
Command Status
16-bit integer
172
Command Response Int16
16-bit integer
173-174
Command Response Int32
32-bit integer
175-176
Comand Response
Float
177-178
Command Response Length
32-bit integer
179-228
Command Response Data
100 Byte Array
229-239
reserved
16-bit integer
240
Barcode Count
16-bit integer
241
Barcode-1 Type
16-bit integer
242
Barcode-1 Length
16-bit integer
243-260
Barcode-1 Data
32-bit 32-byte array
261
Barcode-2 Type
16-bit integer
262
Barcode-2 Length
16-bit integer
263-280
Barcode-2 Data
32-bit 32-byte array
281
Barcode-3 Type
16-bit integer
282
Barcode-3 Length
16-bit integer
283-300
Barcode-3 Data
32-bit 32-byte array
301
Barcode-4 Type
16-bit integer
302
Barcode-4 Length
16-bit integer
iVu Plus BCR Gen2 Series Sensor
128