Numeric ID
Text ID
Description
10152
NOT_READABLE
Attempt to get a value that is not readable
10153
NOT_WRITEABLE
Attempt to set a value that is not writeable
10250
NOT_A_METHOD
Method ID specified is not a method
10251
WRONG_ARGUMENT_COUNT
Total method arguments specified do not match method
10252
COMMAND_NOT_FINISHED
Attempt to issue command when a previous command has not
finished
10300
SET_WITH_ARGUMENT_TYPE_INVALID
Item ID specified must be an item (not a group or method)
10301
DATA_VALUE_MISSING
Command missing item's data value
10340
MINIMUM_VALUE_EXCEEDED
New item value is below the minimum
10341
MAXIMUM_VALUE_EXCEEDED
New items value is above the maximum
10350
ARGUMENTS_DETECTED
Get command received with unneeded arguments
10351
GET_WITH_ARGUMENT_TYPE_INVALID
Item ID specified must be an item (not a group or method)
10500
DATA_SET_EMPTY
Data export operation returned no results
10900
SENSOR_NOT_READY
Command specified requires the iVu BCR to be in the READY
state
10920
SENSOR_TYPE_NOT_ACTIVE
Command specified belongs to a different sensor type
15000
VALUE_INVALID
Text value is invalid / unknown
15050
VALUE_INVALID
Text value is invalid - expecting True or False
15100
STRING_TOO_LONG
String value specified exceeds maximum allowable length
20000
BARCODE_TIMEOUT
Attempt to obtain Barcode result data when decoder has timed
out
20001
NO_BARCODES_FOUND
Attempt to obtain Barcode result data when no barcodes were
found
20002
COMPARE_DATA_DISABLED
Operation requires Barcode compare to be enabled
20003
COMPARE_MASK_INVALID
Compare mask invalid. Expecting string of 1's and 0's with length
equal to compare data string
20004
NUMBER_TO_FIND_NOT_ONE
Barcode number to find must be set to one for this operation
80000
REMOTE_DISPLAY_NOT_CONNECTED
Remote Display must be connected to obtain this value
80001
REMOTE_DISPLAY_NOT_SUPPORTED
This device does not have Remote Display capability
80100
COMMAND_MODE_EXPECTED
The Trigger Mode must be set to Command perform this operation
80101
COMMAND_TIMED_OUT
The command timed out before finishing
80102
TRIGGER_REQUIRED
Access to the specified data requires a triggered inspection
80103
TRIGGER_NOT_GATED
Command requires a active Gated Trigger
80150
COMMAND_TIMED_OUT
The command timed out before finishing
80200
SYSTEM_ERROR_NOT_ACTIVE
A System Error must be active to execute this command
13.5
iVu BCR
Discovery Protocol
The iVu BCR Discovery Protocol is a method to dynamically discover Banner iVu BCR devices on an Ethernet network.
The goal is to both be able to find a device and, if necessary, change the IP address of that device so that it is on the same
subnet as the controlling PC. This is done without requiring the PC to change its IP address or using anything more than an
Ethernet cable connected to the device.
iVu Plus BCR Gen2 Series Sensor
92