Figure 120. Connection Screen
3. Click (only one time) on the Arrow button on the bottom left to return to the Industrial Ethernet window.
Figure 121. Industrial Ethernet Menu
4. Click Map to configure the PROFINET module map.
Figure 122. PROFINET Module Map Screen
Note: The PROFINET module map displays S1 SS1 and S1 SS2 by default. S1 represents Slot 1,
SS1 represents SubSlot 1; S2 represents Slot 2, SS2 represents SubSlot 2. The other slots are
not configured by default.
The default PROFINET configuration consists of a single module plugged into Slot 1. This module, called the Device
Control and Status Module, accepts two submodules: the Inspection Result Submodule, plugged into Subslot 1,
and the Device Control Submodule, plugged into Subslot 2.
The Inspection Result Submodule provides the inspection results from the iVu BCR, including Pass Count, Fail
Count, and Current Inspection Time. See
(p. 134).
Note: The Inspection Result Submodule does not provide any barcode output data.
The Device Control Submodule allows you to issue commands to the iVu BCR, such as Trigger, TEACH, and
Product Change. This submodule also provides command feedback. See
(p. 134).