![Banner iVu Plus BCR Gen2 Series Instruction Manual Download Page 30](http://html1.mh-extra.com/html/banner/ivu-plus-bcr-gen2-series/ivu-plus-bcr-gen2-series_instruction-manual_4021075030.webp)
D
C
A
B
E
C
A
C-Mount Lens
B
Lens Enclosure
C
Retainer Ring
D
Filter
E
Filter Retainer Ring Tool
Figure 21. C-Mount Lens Model Components
Note: The retainer ring (C) and filter (D) are optional. Filter kits are available separately.
6.2 Setting Up a Barcode Application
This section describes how to set up the iVu BCR sensor.
1. Go to Main Menu > Inspection > Barcode > Barcode Type .
2. Select one or more Barcode Types from the list.
Note: To ensure optimal performance, select only the barcode types for your application. For
example, if you use only one of the of the barcode types listed for All Linear, uncheck the box
next to All Linear, and select the desired linear barcode type. If you use only DataMatrix, uncheck
all the boxes except the one next to DataMatrix.
3. Go to Main Menu > Inspection > Barcode > Barcode Count to select the number of barcodes (1 to 10) to be read at
one time.
After the sensor has been set up as described:
• Each successfully read barcode is marked by a green bounding box. If annotations are on, the barcode data is also
displayed.
iVu Plus BCR Gen2 Series Sensor
30
www.bannerengineering.com - Tel: + 1 888 373 6767