Error Code
Description
Recommended Solution
10091
Receiving data from the sensor
timed out (no data was received).
The connection to the sensor was
aborted by this application.
• Verify the network adaptor link speed and duplex settings
• Verify the is sensor not stalled, or in shutdown mode
10092
Receiving data from the sensor
timed out (partial data was
received). The connection to the
sensor was aborted by this
application.
• Verify the network adaptor link speed and duplex settings
• Verify the is sensor not stalled, or in shutdown mode
10093
A parsing error was detected while
receiving data from the sensor. The
connection to the sensor was
aborted by this application.
• Verify the network adaptor link speed and duplex settings
• Verify the is sensor not stalled, or in shutdown mode
10094
A receive overrun was detected
while receiving data from the
sensor. The connection to the
sensor was aborted by this
application.
• Verify the network adaptor link speed and duplex settings
• Verify the is sensor not stalled, or in shutdown mode
10095
Receiving data from the sensor
timed out (internal error). The
connection to the sensor was
aborted by this application.
• Verify the network adaptor link speed and duplex settings
• Verify the is sensor not stalled, or in shutdown mode
10096
A transmit timeout occurred while
sending data to the sensor (no data
was sent). The connection to the
sensor was aborted by this
application.
• Verify the network adaptor link speed and duplex settings
• Verify the is sensor not stalled, or in shutdown mode
10097
A transmit timeout occurred while
sending data to the sensor (partial
data was sent). The connection to
the sensor was aborted by this
application.
• Verify the network adaptor link speed and duplex settings
• Verify the is sensor not stalled, or in shutdown mode
10100
The connection to the sensor was
lost while sending data.
• Install an newer version of this application
• Verify the device at the specified IP address is a Banner Vision
sensor
• Verify the sensor's firmware version is compatible with this
application
• Check the firewall setup on computer
• Go to Sensor Neighborhood and reconnect to the sensor
10101
The connection to the sensor was
lost while sending data.
• Install an newer version of this application
• Verify the device at the specified IP address is a Banner Vision
sensor
• Verify the sensor's firmware version is compatible with this
application
• Check the firewall setup on computer
• Go to Sensor Neighborhood and reconnect to the sensor
10110
The connection to the sensor was
aborted by this application due to
an internal processing error.
• Install an newer version of this application
• Verify the device at the specified IP address is a Banner Vision
sensor
• Verify the sensor's firmware version is compatible with this
application
• Check the firewall setup on computer
• Go to Sensor Neighborhood and reconnect to the sensor