PCB14 P84
Bus ignore mode
If an error occurs in the IIC bus system which makes the TV go into stand-by every
time it is attempted to be switched on, it is possible to switch on the TV in such a
way that the error is ignored:
- The TV must be on stand-by for at least 5 seconds.
- Short-circuit the service socket, P84 on AV Switch PCB14, coordinate 5L, for a
minimum of 0.5 second.
- Remove the jumper.
- Press
TV
. The TV will now start up in the bus ignore mode if that is possible.
Service mode, English 5.21