Error Code
Module no.
D0
14
94
14
96
14
90
14
80
14
22
7
88
2
68
2
42
2
40
2
C0
1
80/84/88
1
8C
5
84
32
68
61
C8
63
48
9
5C
997
Survey of Error Codes
Access to Service Mode
Select
TV MENU
and select Setup.
Press
0 0 GO
within 3 seconds.
Reading the error code
To read an error code from the television you must access the Service Mode. Then
select
MONITOR -> MONITOR INFORMATION
. If the television has registered an
error, the error code will be shown in this menu under
ERROR
.
The table shows which module has generated an error code on IIC bus.
Error Code
TV error
.....
No error registered
DF
Data faliure
OL-D
Overload deflection
OL-S
Overload sync
MDL
Megatext deadlock
MRF
Megatext reset faliure
XX-YZ
(XX = IIC address. Y = IIC bus address,
bus 1 or bus 2.
Z = any IIC bus segment A/B/C/D)
Error Code
ML/SL error
.....
No error registered
CI
Address configuration impossible
TD
ML data pulled down
TU
ML data pulled up
Other undefinable error possibilities
Deleting the error codes
After repair of an error that has triggered the display of an error code, the
error code has to be deleted. This is done by pressing
GO
in the
MONITOR
INFORMATION
menu.
Service mode, English 5.15
ABO-CENTER
v/HENRIKSENS
ELEKTRONIK